12
12
5
7. Heater
Measure resistance of the
following terminal
Terminal: 1 (COM) - 2
Terminal: 1 (COM) - 3
Terminal: 2 - 3
11. Igniter
Measure resistance from
terminal to terminal.
12. Frame Detect
Measure resistance of the
following terminal
Valve 1 terminal
Valve 2 terminal
Measure resistance of termina
to terminal
Open at 370°F (Maximum)
Close at 320°F
8. Thermistor
Measure resistance of terminal
to terminal
Temperature condition:
9. Motor
• See Page 14
10. Gas valve
Resistance value: 10
Ω
Resistance value: 10
Ω
Resistance value: 20
Ω
Resistance value: 10
Ω
• Electric type
• Heater case
Hi limit
• Electric type
• Gas type
• Gas type
• Gas type
Resistance value: 50~800
Ω
Resistance value: >1.5k
Ω
Resistance value: >1.5~2.5k
Ω
Resistance value
Resistance value < 1
Ω
valve 1
valve 2
Component Test Procedure Check result
Remark
58°F ~ 104°F (10~40°C)
Содержание DLE4970 Series
Страница 31: ...31 31 VALVE 1 IGNITER VALVE 2 FLAME DETECT NO NO YES YES ...
Страница 34: ...34 PANEL REAR COMMON 1 Remove 3 screws remained on the panel rear 2 Lift out the panel rear ...
Страница 43: ...43 Φ Φ Φ Φ ...
Страница 46: ...46 ...
Страница 47: ...47 4 ...
Страница 50: ...50 ...
Страница 54: ...54 ...
Страница 55: ...55 ...
Страница 61: ...61 APR 2016 PRINTED IN KOREA P No MFL62119977 ...