27
INSTALLATION
ENGLISH
Installation Test (Duct Check)
Once you have completed the installation of the
dryer, use this test to make sure the condition of the
exhaust system is adequate for proper operation of
the dryer. This test should be performed to alert you
to any serious problems in the exhaust system of
your home.
•
This dryer features Flow Sense™, an innovative
sensing system that automatically detects
blockages and restrictions in dryer ductwork.
Keeping ductwork clean of lint buildup and free of
restrictions allows clothes to dry faster and reduces
energy use.
NOTE
The dryer should be cool before starting this test.
If the dryer was warmed up during installation,
run the Secado Con Aire(Air Dry) cycle for a few
minutes to reduce the interior temperature.
To activate the installation test:
1
Remove the drying rack and literature, and
then close the door.
Do not load anything in the drum for this test, as
in may affect the accuracy of the results.
2
Press and hold the Anti Arrugas (Wrinkle
Care) and Temp. buttons and then press the
Encendido/Apagado (Power) button.
(On models with a glass touch control panel,
press the
Encendido/Apagado (Power)
button
then IMMEDIATELY press and hold the
Temp.
and Anti Arrugas (Wrinkle Care) buttons.)
This button sequence activates the installation
test. The code
will display if the activation is
successful.
3
Press the Inicio/Pausa(Start/Pause) button.
The dryer will start the test, which will last about
2 minutes. The heat will be turned on and the
temperatures in the drum will be measured and
displayed. A chime sounds when the test portion
of the cycle is complete.
4
Check the display for results.
During the test cycle, monitor the Flow Sense™
display on the control panel. If the Flow Sense™
LED has not turned on, when the cycle ends,
the exhaust system is adequate. If the exhaust
system is severely restricted, the Flow Sense™
LED will turn on. Other problems may also be
shown with error codes. See the chart on the
next page for error code details and solutions.
LED turned on:
RESTRICTED
The Flow Sense™ LED indicates that the
exhaust system is severely restricted. Have the
system checked immediately, as performance
will be poor.
5
End of cycle.
At the end of the test cycle,
will display.
The test cycle will end and the dryer will shut off
automatically after a short delay.
•
Check the error code before you call for service
Error
Code
Possible
Causes
Solutions
tE1
or
tE2
•
Temperature
sensor
failure.
•
Turn off the dryer and
call for service.
HS
•
Humidity
sensor failure.
•
Turn off the dryer and
call for service.
PS
or PF
or nP
•
Electric
dryer power
cord is not
connected
correctly, or
house power
supply is
incorrect.
•
House fuse is
blown, circuit
breaker
has tripped,
or power
outage has
occurred.
•
Check the power
supply or the
connection of the
power cord to the
terminal block. Refer
to the
Connecting
Electric Dryers
section of this
manual for complete
instructions.
•
Reset circuit breaker
or replace fuse. Do
not increase the
fuse capacity. If the
problem is a circuit
overload, have
it corrected by a
qualified electrician.
gAS
•
Gas supply or
service turned
off. (Gas
Model only.)
•
Confirm that house
gas shutoff and the
dryer gas shutoff are
both fully open.