background image

E-10

For Windows NT Workstation Ver. 4.0 Users

In order to ensure normal drive operation, please check the following:
¥

The drive is displayed on the IDE controller in 
[control panels] - [SCSI adapter] - [devices]

If the drive is not recognized by your computer, please check the following
items.
¥

If a        indicator is displayed on the IDE controller in [control panels]-
[SCSI adapter]-[devices], you will need to contact your PCÕs manufacturer
or the motherboardÕs manufacturer and get the appropriate IDE controller
driver.

Emergency Eject

This drive has a function that allows the CD to be ejected manually if this
becomes necessary in an emergency, such as failure of the drive or a power
outage. Follow this procedure in such a case.

NOTE:

DonÕt use this feature except in an emergency.

1) Turn the power to OFF.
2) Poke a fine-tipped object (such as a straightened heavy duty paper clip) into

the small hole at the front. The front door will pop open and the disk tray will
come partway out.

3) Pull the front door to open it all the way, then grip the disc tray between

thumb and forefinger and gently pull it straight out.

NOTE:

This feature is a last measure to be used only in an emergency. Using it

excessively will cause malfunction.

COMPACT

CRD-8480B/C-eng*  8/13/99 10:54 AM  Page 10

Содержание CRD-8480B

Страница 1: ...D EMPLOI MANUALE D USO MANUAL DE USUARIO To enjoy fully all the features and functions of your CD ROM Drive Please read this Owner s Manual carefully and completely website http www LGEservice com e mail http www LGEservice com techsup html CRD 8480B C eng 8 13 99 10 53 AM Page 1 ...

Страница 2: ...nce in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception w...

Страница 3: ...General Manager Multimedia Standards Team We hereby declare that the equipment bearing the trade and model number specified above was tested conforming to the applicable FCC Rules under the most accurate measurement standards possible and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the CommissionÕs...

Страница 4: ...stem Requirement IBM PC AT or compatible 486 SX 25 processor or higher Pentium 133 Processor or higher recommended 640 Kb memory 16Mb or higher recommended A suitable free standard 51 4Ò internal drive bay MS DOS version 3 1 or higher Windows 95 and above recommended 31 2Ó 1 44 Mb Floppy Drive An existing IDE controller with an available cable connector or a new IDE controller recommended with IDE...

Страница 5: ...t View Back View Supplied Accessories zOwnerÕs Manual zDevice Driver MS DOS zAudio Cable COMPACT 1 2 5 4 6 7 3 DIGITAL ANALOG INTERFACE POWER D R C S M S L A G L G 39 1 5 12 GND 40 2 AUDIO AUDIO 1 2 5 4 3 CRD 8480B C eng 8 13 99 10 54 AM Page 5 ...

Страница 6: ...e next track 7 Open Close Stop Button This button is pressed to open or close the CD tray If an audio CD is playing pressing this button will stop it and pressing it again will open the tray Back View 1 Digital Audio Output Connector This is a digital audio output or Video CD output connector You can connect this to a digital audio system or a Video CD Board 2 Analog Audio Output Connector The Aud...

Страница 7: ...se a splitter cable of a suitable type The red edge of the IDE cable corresponds to pin 1 of the IDE interface on the CD ROM drive Please Note an IDE cable is not supplied and may be required to be purchased separately If the computer is using a sound card the drive is connected to the sound card with an audio cable This CD ROM drive is supplied with a Creative Labs SoundBlaster compatible audio l...

Страница 8: ...o connect CD ROM drive to the Secondary IDE port and set to Master position 5 When the installation of the drive unit is complete replace the computer cover 6 Reconnect the computer power cord and turn on the computer DIGITAL ANALOG INTERFAC E POWER D R C S M S L A G L G 39 1 5 12 GND 40 2 AUDIO AUDIO DIGITAL ANALOG INTERFAC E POWER D R C S M S L A G L G 39 1 5 12 GND 40 2 AUDIO AUDIO DIGITAL ANAL...

Страница 9: ...ve with DOS booting 2 Go to the floppy drive by typing A or B at the DOS prompt as appropriate 3 Type the word INSTALL and press ENTER 4 The INSTALL program will begin loading When loading is complete the INSTALL program identification will appear on screen 5 Follow the instructions on screen 6 When installation is complete remove the diskette and reboot your PC For Windows 98 95 Users In order to...

Страница 10: ... has a function that allows the CD to be ejected manually if this becomes necessary in an emergency such as failure of the drive or a power outage Follow this procedure in such a case NOTE DonÕt use this feature except in an emergency 1 Turn the power to OFF 2 Poke a fine tipped object such as a straightened heavy duty paper clip into the small hole at the front The front door will pop open and th...

Страница 11: ...ype is IDE type 3 Check your hard disk Master Slave Jumper setting Some old version IDE type hard disks were set to Master Only mode In that case contact your hard disk company and change your hard disk jumper setting to master mode 4 If the CD ROM drive does not work with above methods you may need a secondary IDE card If you use the secondary IDE card you should set the CD ROM drive jumper to th...

Страница 12: ...er size 128 Kbytes Error Rate ECC on 1 block 1015 bits 48x ECC off 1 block 1012 bits 48x User Data Block 2 048 bytes block Mode1 Mode2 Form1 2 340 2 336 bytes block Mode2 2 324 bytes block Mode2 Form2 2 352 bytes block CD DA Supported Disc CD DA CD ROM CD ROM XA READY Photo CD CD Plus CD Extra Mixed CD CD RW Frequency Response 20 Hz 20 KHz 1 3 dB S N Ratio 85 dB THD 0 05 at 1 KHz Channel Separatio...

Страница 13: ...u may also have other rights which vary from state to state 1 Year 1 Year No other express warranty is applicable to this product THE DURATION OF ANY IMPLIED WARRANTIES INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO THE DURATION OF THE EXPRESS WARRANTY HEREIN LG ELECTRONICS U S A INC SHALL NOT BE LIABLE FOR THE LOSS OF THE USE OF THE PRODUCT INCONVENIENCE LOSS OR ANY OTHER DAMAGES...

Страница 14: ...ylvan Ave Englewood Cliffs NJ 07632 U S A LG Electronics Canada Inc 235 Superior Blvd Mississauga Ontario Canada LG Electronics Deutschland GMBH Jakob Kaiser Straße 12 D 47677 Willich Germany LG Electronics U K Ltd LG House 264 Bath Road Slough Berkshire SL1 4DT United Kingdom LG Goldstar France SARL 12 Rue Lech Walesa Z I Pariest 77185 Lognes France LG Electronics Italia S P A Centro Direzione IL...

Отзывы: