SAFETY INSTRUCTIONS
ENGLISH
• Compliance with national gas regulations shall be observed.
• Any person who is involved with working on or breaking into a refrigerant circuit
should hold a current valid certificate from an industry accredited assessment
authority, which authorizes their competence to handle refrigerants safely in
accordance with an industry recognized assessment specification. (for R32)
• Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be
carried out under the supervision of the person competent in the use of flammable
refrigerants. (for R32)
Installation
• Do not use a defective or underrated circuit breaker. Use the correctly rated breaker
and fuse. There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair the product by yourself. There is risk of
fire or electric shock.
• Always ground the product as per the wiring diagram. Do not connect the ground
wire to gas or water pipes lightening rod or telephone ground wire. There is risk of
fire or electric shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric
shock due to dust, water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. If the power cable or cord has scratches
or skin peeled off or deteriorated then it must be replaced. There is risk of fire or
electric shock.
• For installation, removal or reinstall, always contact the dealer or an Authorized
Service Center. There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. Be sure that the
installation area does not deteriorate with age. It may cause product to fall.
• Never install the outdoor unit on a moving base or a place from where it can fall
down.
The falling outdoor unit can cause damage or injury or even death of a person.
• In outdoor unit the step-up capacitor supplies high voltage electricity to the electrical
components. Be sure to discharge the capacitor completely before conducting the
repair work. An charged capacitor can cause electrical shock.
• When installing the unit, use the installation kit provided with the product. Otherwise
the unit may fall and cause severe injury.
• Indoor/outdoor wiring connections must be secured tightly and the cable should be
routed properly so that there is no force pulling the cable from the connection
terminals. Improper or loose connections can cause heat generation or fire.
Содержание CL09F
Страница 18: ...18 ENGLISH ...
Страница 36: ...18 ITALIANO ...
Страница 54: ...18 ESPAÑOL ...
Страница 72: ...18 FRANÇAIS ...
Страница 90: ...18 DEUTSCH ...
Страница 108: ...18 ΕΛΛΗΝΙΚΆ ...
Страница 126: ...18 ČEŠTINA ...
Страница 144: ...18 NEDERLANDS ...
Страница 162: ...18 POLSKI ...
Страница 180: ...18 LIMBA ROMÂNĂ ...
Страница 181: ......