73
A. Start
1. Install CED-8041B –> PC Power ON –> Execute Windows
2. Execute Dragon.exe on Windows (Dragon.exe & dragon.cfg Should be on same Directory)
3. Select “Setup” – “Setup I/F” on menu.
4. Select “ATAPI I/F” on ‘Select I/F Methed’ –> Click “OK”
(Don’t select “Select Transfer Rate”)
5. Select “Setup”- “Target Select” on menu.
6. Select appropriate “Host Adapter” on ‘Target Select’ Window.
–> ‘0-0 : CED-8041B’ will come out on ‘Target Device’
7. Select “CED-8041B” on ‘Target Device’ –> Click “OK”
B. Check Calibration Data
1. Select “Calibration” - “Calibration” on menu.
2. Click “Read” on ‘Calibration’ window
–> Results (hex data) will come out.
3. Check Data
CD-R VRDC DAC
: 32~5F
CD-RW VRDC DAC
: 28~55
VWDC1 DAC
: 40~A0
VWDC2 DAC
: 78~C8
SPP
: 90~B8
Focus Bias
: Not use
4. Close ‘Calibration’ window.
C. Calibration
1. Select “Calibration” - “Calibration” on menu.
2. Inserting Test Disc (TCD - 784) on Tray –> Load Disc.
3. Click “Start” on ‘Calibration’ window
4. Tray will be ejected after Calibration
–> ‘Calibration Data (hex)’ will come out.
5. Check Data.
6. Close ‘Calibration’ window.
• How to use Test Tool (Dragon)
[I/F Setting window]
[Target Select window]
[Calibration window]