4.10 Vibrator Trouble
START
Is the voltage at pin 3 of
Q500 near 0V?
Check the soldering
of R500
Check the signal level
of CN500
Replace Vibrator
Vibrator
Working!!
Check the soldering of
R501
Replace Q500
No
No
No
Yes
Yes
Yes
Yes
No
Yes
Re-solder R500
Re-solder Vibrator connector
Re-solder R501
4. TROUBLE SHOOTING
SETTING : After initialize Agilent 8960, Test in EGSM, connect PIF to the phone,
and Power on. Enter The engineering mode, and set “Vibrator on” at Vibration
of BB test menu
Содержание C3100
Страница 1: ...Service Manual Model C3100 Service Manual C3100 P N MMBD0033001 Date June 2004 Issue 1 0 ...
Страница 51: ...Graph 4 15 EGSM TX 50 VCX VC2 VCX VC2 4 TROUBLE SHOOTING Graph 4 14 DCS TX ...
Страница 67: ...5 DISASSEMBLY INSTRUCTION Figure 5 1 Figure 5 2 66 5 DISASSEMBLY INSTRUCTION ...
Страница 68: ... 67 5 DISASSEMBLY INSTRUCTION Figure 5 3 Figure 5 4 ...
Страница 69: ... 68 Figure 5 5 5 DISASSEMBLY INSTRUCTION ...
Страница 70: ... 69 5 DISASSEMBLY INSTRUCTION Figure 5 6 Figure 5 7 1 3 2 4 1 2 3 ...
Страница 71: ... 70 Figure 5 8 Figure 5 9 5 DISASSEMBLY INSTRUCTION 4 2 3 1 2 1 ...
Страница 72: ... 71 5 DISASSEMBLY INSTRUCTION Figure 5 10 ...
Страница 83: ... 82 7 BLOCK DIAGRAM 7 BLOCK DIAGRAM Power supply ...
Страница 90: ... 89 9 PCB LAYOUT 9 PCB LAYOUT ...
Страница 91: ... 90 9 PCB LAYOUT ...
Страница 98: ... 97 11 3 HW Test Software for Standalone Test Setup 11 STAND ALONE TEST ...
Страница 100: ... 99 Tx Stand alone Test Setting 11 STAND ALONE TEST ...
Страница 102: ... 101 Rx Stand alone Test Setting 11 STAND ALONE TEST ...
Страница 104: ... 103 12 3 Equipment Setup Figure 12 1 Equipment Setup 12 AUTO CALIBRATION ...
Страница 107: ... 106 12 AUTO CALIBRATION ...
Страница 108: ... 107 13 EXPLODED VIEW REPLACEMENT PART LIST 13 EXPLODED VIEW REPLACEMENT PART LIST 13 1 Exploded View ...
Страница 109: ... 108 13 EXPLODED VIEW REPLACEMENT PART LIST ...