24
INSTALLATION OF DECORATIVE PANEL(ACCESSORY)
ENGLISH
4
Tape the Pipings and Connecting cable
from bottom to top.
5
Form the pipings gathered by taping along
the exterior wall, and make the trap pre-
vent water from entering into the room.
6
Fix the pipings onto the wall by saddle or
equivalent
In case of the Outdoor Unit being
installed above position of the Indoor
Unit.
Seal a small opening
around the pipings
with gum type sealant.
Trap
Air Purging
Air purging
The air and moisture remaining in the refriger-
ant system have undesirable effects as indi-
cated below.
- Pressure in the system rises.
- Operating current rises.
- Cooling(or heating) efficiency drops.
- Moisture in the refrigerant circuit may freeze
and block capillary tubing.
- Water may lead to corrosion of parts in the
refrigeration system.
Therefore, after evacuating the system, take a
leak test for the piping and tubing between
the indoor and outdoor unit.
Air purging with vacuum pump
- Check that both liquid and gas pipe between
indoor and outdoor have been properly con-
nected.
- Remove the service valve cap from both the
gas and liquid side on the outdoor unit.
- Confirm that both the liquid and gas side
valve are set to the closed position.
- Connect the manifold valve(with pressure
gauge) to the gas pipe side.
Lo
Hi
Indoor unit
Outdoor unit
Manifold valve
Charge hose
Nitrogen gas
cylinder(in vertical
standing position)
Pressure
gauge