- 39 -
Copyright ©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
Operation
• Power relay turns on 1 second later after the power is input to the outdoor unit.
• Control sequence : power on
➔
PTC operating
➔
power relay on
■
CT1 control
• If the operating current reaches I1, the operating frequency of the compressor decrease.
• After decreasing the operating frequency by 1step, if operating current is below I1 for 60 seconds continuous-
ly, the operating frequency of compressor increase by 1step.
■
CT2 control
• If the operating current of the appliance reaches I2, the compressor stop instantly and 2 minutes later the
compressor restart again.
• If CT2 occurs 5 times within 1hour, the appliance turn off and display ERROR CODE 7.
❇
I1:Current of operating frequency down
I2: Current of compressor cut off
cf. I1 is set the lowest level between intial value and in case dectection of dc paeak current.
Control table
■
DC Peak Current Error by a fault signal of IPM
• If the operating current of IPM reaches 35A ±3A, the compressor stop instantly.
• If DC PEAK occurs 5 times within 1 hour, the appliance turns off and display ERROR CODE 6.
■
DC Peak Current Error by the compressor lock
• If the DC LINK voltage below DC 140V occurs 5 times within 1 hour while the compressor is operating, the
appliance turns off and display ERROR CODE 6.
■
DC Peak Current Error by the Outdoor Fan Lock
• If it’s 5 times within 1 hour in case of the temperature of outdoor pipe TH is over 65°C while the compressor is
operating, the appliance turns off and display ERROR CODE 6.
Power relay control
Protection from total current control
Protection from DC Peak Current
1 AS-W096DH0/DH1/GH0
5.5
6.5
6
7
9
2 AS-W126DH0/GH0
6.5
7.5
7
8
10
3 AS-W1865DH0
9
10.5
9.5
11
13
4 AS-W1224DH0
6
6.5
6.5
7
8.5
5 AS-W1424DH0
6
6.5
6.5
7
9
6 AS-W1825DH0
10.5
11.5
11
12
14
7 AS-W096E1G0
7
8.5
7.5
9
10
8 AS-W126E1G0
7
8.5
7.5
9
10
I1
Cooling
Heating
Cooling
Heating
Outdoor temp
≥
38°C
Outdoor temp < 38°C
I2
Model
Содержание AS-W0964DH0