Service Manual
3
7
Disassembly
Disassembly
Indoor Unit
Disconnect the unit from power supply before mak-
ing any checks.
Be sure the power switch is set to “OFF”.
To remove the Grille from the Chassis.
• Set the up-and-down air discharge louver to open
position (horizontally) by finger pressure.
• Remove the securing screws.
• To remove the Grille, pull the lower left and right
side of the grille toward you (slightly tilted) and lift it
straight upward.
1. Before removing the control box, be sure to
take out the wire screwed at the other end.
Earth
Conductor
Содержание AS-C0764DB0
Страница 11: ...Service Manual 11 Dimensions Installation plate D H W W mm 840 H mm 270 D mm 161 Model Dimension SY Chassis ...
Страница 36: ...3 4 36 Service Manual ...
Страница 40: ...40 Room Air Conditioner Schematic Diagram Schematic Diagram Electric Control Device Heat Pump Model LED TYPE ...
Страница 44: ...44 Room Air Conditioner Schematic Diagram Components Location MAIN P W B ASSEMBLY TOP VIEW BOTTOM VIEW ...
Страница 45: ...Service Manual 45 Schematic Diagram DISPLAY ASSEMBLY ...
Страница 68: ......