background image

ON

OFF

CANCEL

AUTO CLEAN

SET

6

Safety Precautions

Operating Instructions

Care and Maintenance

Troubleshooting Tips

Care and Maintenance

Operating Instructions

Safety Precautions

1

3

5

4

9

10

17

18

16

7

2

8

13

14

15

11

6

Cooling Operation

Auto Operation

Healthy Dehumidification Operation

Flip-up door
(opened)

Heating Operation

Signal transmitter

• Cooling Model(

), Heat Pump Model(

)

12

About the remote control on the system

The remote control transmits the signals to the system.

Features of the Remote Control- Door Opened

Operation Mode

START/STOP BUTTON
Operation starts when this button is pressed
and stops when the button is pressed again.
OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
INDOOR FAN SPEED SELECTOR
Used to select fan speed in four steps
low, medium, high and CHAOS.
JET COOL
Used to start or stop the speed 
cooling. (Speed cooling operates 
super high fan speed in cooling mode.)
CHAOS SWING BUTTON
Used to stop or start louver movement and set
the desired up/down airflow direction.
ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation. (See page 14)
TIME SETTING BUTTONS
Used to adjust the time. (See page 14)
TIMER SET/CANCEL BUTTON
Used to set the timer when the desired time is
obtained and to cancel the Timer operation.
(See page 14)
SLEEP MODE AUTO BUTTON
Used to set Sleep Mode Auto operation. 
(See page 14)
AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating. (See page 15)
ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
PLASMA(OPTIONAL)
Used to start or stop the plasma-purification
function. (See page 12)
HORIZONTAL AIRFLOW DIRECTION
CONTROL BUTTON  (NOT ON ALL MODELS)
Used to set the desired horizontal airflow
direction. (See page 15)
RESET BUTTON
Used prior to resetting time or after replacing
batteries.
2nd F Button
Used prior to using modes printed in blue at the
bottom of buttons. (See page 13)
AUTO CLEAN
Used to set Auto Clean mode.
LED LUMINOSITY
Used to adjust LED luminosity.

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

Содержание AS-C07 Series

Страница 1: ...ung children should be supervised to ensure that they do not play with the appliance Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 3 Norm MODELS LS C07_Series LS H07_Series LS C09_Series LS H09_Series LS C12_Series LS H12_Series AS C07_Series AS H07_Series AS C09_Series AS H09_Series AS C12_Series AS H12_S...

Страница 2: ... will cause electric shock or fire due to heat generation It will cause electric shock or fire In the supply cord is damaged it mut be replaced by the manufacturer or its service agent or a similarly quallfied person in order to avoid a hazard Y Attachment Do not modify power cord length or share the outlet with other appliances Do not operate with wet hands or in damp environment Do not direct ai...

Страница 3: ...rniture It may cause electric shock and damage It may cause failure of product or fire Do not place obstacles around the absorption inlet or instead of blowing out inlet Ensure that an installation console of the outdoor appliance is not damaged due to the use for a long time Always insert the filters securely Clean it once every two weeks It may cause failure of appliance or accident If leaving a...

Страница 4: ...ote control may be stored by mounting it on a wall To operate the room air conditioner aim the remote control at the signal receptor How to Insert the Batteries Remove the battery cover by pulling it according to the arrow direction Insert new batteries making sure that the and of battery are installed correctly Reattach the cover by sliding it back into position NOTES Use 2 AAA 1 5volt batteries ...

Страница 5: ... Cleaning Mode Lights up during Auto Cleaning reservation Jet Cool Mode Lights up during Jet Cool Operation Plasma Lights up during Plasma operation Fan Speed Low Lights up when Fan speed is low Fan Speed Medium Lights up when Fan speed is Medium Fan Speed High Lights up when Fan speed is High Fan Speed Chaos Lights up when Fan speed is Chaos Desire temperature For cooling dehumidification heating...

Страница 6: ...high fan speed in cooling mode CHAOS SWING BUTTON Used to stop or start louver movement and set the desired up down airflow direction ON OFF TIMER BUTTONS Used to set the time of starting and stopping operation See page 14 TIME SETTING BUTTONS Used to adjust the time See page 14 TIMER SET CANCEL BUTTON Used to set the timer when the desired time is obtained and to cancel the Timer operation See pa...

Страница 7: ...ted in the direction of the arrow Close the door on the remote control Set the temperature lower than the room temperature The temperature can be set within a range of 18 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shifted ...

Страница 8: ...rols based on the actual room temperature If you want to change the set temperature press the Room Temperature Setting buttons The cooler or warmer you feel the more times up to two times you should press the button The set temperature will be changed automatically During Auto Operation You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating ...

Страница 9: ...e sensed current room temp In this case however the setting temp is not displayed in the remote control and you are not able to control the room temp either During the healthy dehumidification function the airflow volume is automatically set according to the optimization algorithm responding to the current room temp status which makes the room condition healthy and comfortable even in the high hum...

Страница 10: ...ifted in the direction of the arrow Close the door on the remote control Set the temperature higher than the room temperature The temperature can be set within a range of 16 C 30 C in 1 C increments Set the fan speed again with the door of the remote control still closed You can select the fan speed in four steps low medium high and CHAOS Each time the button is pressed the fan speed mode is shift...

Страница 11: ...le In order to return to the normal cooling mode from the JET COOL mode you just press either the operation mode selection button airflow volume selection or temp setting button or the JET COOL button again Press the Start Stop button The unit will respond with a beep Press the Jet Cool button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode for 3...

Страница 12: ...ressed and stop when the button is pressed again 2 Set the fan speed again with door of the remote control closed You can select the fan speed in four steps low medium high or CHAOS Each time the button is pressed the fan speed mode is shifted Air purifying operation PLASMA can be with cooling Heating or any other operations PLASMA Air Purifying Operation only If you press the only PLASMA button o...

Страница 13: ...p Open the door of the remote control and press the 2nd Function button to operate functions printed in blue at bottom of buttons Check the indication of 2nd function on remote control display These buttons operate the timer setting as follows 2nd function goes off in a short time automatically or when the button is pressed again For more details refer to functions next page 2nd F Operation 1 2 3 ...

Страница 14: ...ll automatically rise by 1 C over the next 30 minutes and by 2 C in 1 hour for comfortable sleeping Setting the Time Time can be set only when you have pressed the Reset button If you have just replaced the batteries the Reset button should be pressed to reset the time Press the Start Stop button Press 2nd F button and check if 2nd F icon is on Press the Time Setting buttons until the desired time...

Страница 15: ...own Press the Chaos Swing button again to set the vertical louver at the desired airflow direction Note If you press the CHAOS swing button the horizontal airflow direction is changed automatically based on the CHAOS algorithm to distribute the air in the room evenly and at the same time to make the human body feel most comfortable as if enjoying a natural breeze Always use the remote control to a...

Страница 16: ... the door on the remote control Now each time that you press the start stop button the Air conditioner operates clean function automatically Display Luminosity The Display Luminosity can be adjusted by using the remote control Press the start stop button to start the unit Open the door on the remote control press the 2ndF button and press display luminosity button Display will be dark Press the bu...

Страница 17: ...el Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Helpful information Fan speed and cooling capacity The cooling capacity indicated in the specification is the value when the fan speed is set to high and the capacity will be lower at low or m...

Страница 18: ...in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing with water dry well in the shade 4 Re install the air filter 1 After removing the air filters pull slightly forward to remove the PLASMA filter 2 Dip the PLASMA filter into the water mixed with neutral detergent for 20 30 minutes 3 Dry the PLASMA filter in the shade for a day Especially the humidity must be remo...

Страница 19: ...irt or soot the heat exchanger and panel vents may be professionally steam cleaned NOTE Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs Cleaning of Purifying Filter Recomended use period About 3 months ENGLISH Open the upside of Front panel Put up the front panel The hook of panel comes off Remove air filter and then pull out plasma filter...

Страница 20: ... it in the indoor unit Refer to page 18 for cleaning filters Check that the air inlet and outlet of the indoor outdoor unit are not blocked Do not overcool the room This is not good for the health and wastes electricity Make sure that the doors and windows are shut tight Avoid opening doors and windows as much as possible to keep the cool air in the room Keep blinds or curtains closed Do not let d...

Страница 21: ...ker been tripped Check that this is not a damp smell exuded by the walls carpet furniture or cloth items in the room Condensation occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions Has the temperature been set incorrectly Are th...

Страница 22: ...22 Memo ...

Страница 23: ...P No 3828A20324P After reading this manual keep it in a place easily accessible to the user for future reference Printed in Korea ...

Отзывы: