ProduCT dATA | 11
Product Data
Due to our policy of continuous product innovation, some specifications may change without notification.
gEnEral data
Art Cool Premier Specifications
Table 2: Unit General Data
Type
Art Cool Premier
Art Cool Premier
System (Model)
LA090HYV (LAn090HYV/LAU090HYV)
LA120HYV (LAn120HYV/LAU120HYV)
nominal Cooling Capacity (Btu/h)
9,000
12,000
Cooling Power Input
1
(kW)
0.56
0.85
nominal Heating Capacity (Btu/h)
11,000
13,600
Heating Power Input
1
(kW)
0.70
0.86
Cooling CoP
4.69
4.14
EER
16.01
14.12
SEER
27.5
25.5
HSPF
11.8
11.5
Power Supply (V / Hz / Ø)
208-230/60/1
ODU Operating Range
Cooling (°F DB)
14-118
Heating (°F WB)
(-13)-75
IDU Operating Range
Cooling (°F WB)
64-90
Heating (°F DB)
60-86
Indoor Temperature Setting Range
Cooling (°F)
65-86
Heating (°F)
61-86
Unit Data
Refrigerant Type
2
R410A
Refrigerant Control
EEV
IDU Sound Pressure
3
dB(A) (H/M/L/Sleep)
42/36/25/17
oDU Sound Pressure dB(A)
45
Unit
Weight (lbs)
Indoor Unit (net/Shipping)
25/29
outdoor Unit (net/Shipping)
73/78
Power/Communication Cable
4
(no. x AWG)
4 x 18
Fan
Indoor Type (Qty)
Cross Flow (1)
outdoor Type (Qty)
Propeller (1)
Motor/Drive
Brushless Digitally Controlled/Direct
Airflow Rate
Indoor - Max/H/M/L (CFM)
547/494/417/283
outdoor - Max (CFM)
1,165
EEV: Electronic Expansion Valve IDU: Indoor Unit oDU: outdoor Unit
Power wiring is field supplied and must comply with the applicable local and national codes.
This unit comes with a dry helium charge.
This data is rated 0 ft above sea level, with 24.6 ft of refrigerant line per indoor unit and a 0 ft level
difference between outdoor and indoor units.
Cooling capacity rating obtained with air entering the indoor coil at 80ºF dry bulb (DB) and 67ºF wet
bulb (WB); and outdoor ambient conditions of 95ºF dry bulb (DB) and 75ºF wet bulb (WB).
Heating capacity rating obtained with air entering the indoor unit at 70ºF dry bulb (DB) and 60ºF wet
bulb (WB); and outdoor ambient conditions of 47ºF dry bulb (DB) and 43ºF wet bulb (WB).
1
Power Input is rated at high speed.
2
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or destroy
R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F) under section 608
of CAA.
3
Sound Pressure levels are tested in an anechoic chamber under ISo Standard 1996.
4
All power/communication cables to be minimum 18 AWG, 4-conductor, stranded, shielded and must
comply with applicable and national code.