48
Single Zone
Art Cool Premier W
all Mounted Installation Manual
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
ELECTRICAL WIRING
Indoor Unit Electrical Connections
Overview - Connecting Indoor Unit Electrical Wiring
The general guidelines for connecting electrical and communication cables to the indoor unit are the same for each of the Single Zone Wall
Mounted indoor units. However, the actual connections on the terminal block will differ.
• Be sure that main power to the unit is completely off before proceeding
with these steps. Failure to do so may cause shock or bodily injury.
• Follow all safety and warning information outlined at the beginning
and throughout this manual. Failure to do so may cause bodily injury.
Procedure
Be sure there is no power going through the Single Zone system before
proceeding with these connections as there can be a risk of electrical
shock and bodily injury.
1. At the bottom panel of the indoor unit, unsnap the latches which
cover the phillips screw heads as shown in Figure 60.
• Normally, there are three (3) screws on the panel, however your
indoor unit model may differ.
2. Using a phillips head screwdriver, remove the screws from the
bottom panel of the indoor unit and set aside (Figure 61).
3. Remove the bottom panel (Figure 62).
• Removal is necessary to gain access to the terminal block which is
situated at the bottom of most indoor units.
• Note that the electrical/communications wiring is usually routed
through the back/bottom of the indoor unit (through a knockout
panel) as shown on the next page (Figure 63).
4. Using a screwdriver, connect the wires as shown on the next
• Each wire should be securely attached to the terminal block.
• Pay attention to the location/connection of the green/yellow ground
cable.
Figure 60: Latch over Screws on Bottom Panel, Indoor Unit
Figure 61: Remove Screws from Bottom Panel
Figure 62: Remove (and Reattachment) Bottom Panel
WARNING
WARNING
• Follow all safety and warning information outlined at the beginning
and throughout this manual. Failure to do so may cause unit failure.
• Some units might require you to remove the Control Cover from the
terminal block area. Most Control Covers are attached with a phillips
screw head.
• Connect the electrical cable to the indoor unit by connecting the
wires to the terminals on the control board individually according to
the outdoor unit connection. Be sure that the color of the wires at the
outdoor unit along with the terminal numbers are the same as those
for the indoor unit.