background image

Maintenance and Service

12

Indoor Unit

Maintenance and Service

Before performing any maintenance, turn off the main power to the system.
Never use any of the followings:
• Water hotter than 40°C.

Could cause deformation and/or discoloration.

• Volatile substances.

Could damage the surfaces of the air conditioner.

Air Filters

The air filters behind the front panel / grill should be checked and cleaned once in
every 2 weeks or more often if necessary. To remove the filters see the self
explanatory diagrams for each model type. Clean the filters with a vacuum cleaner
or warm soapy water. If dirt is not easily removed, wash with a solution of
detergent in luke warm water. Dry well in shade after washing and reinstall the
filters back in place.

Plasma Filters

The plasma filters behind the air filter should be checked and cleaned once in every 3
months or more often if necessary. To remove the filters see the self explanatory
diagrams for each model type. Clean the filters with a vacuum cleaner. If it is dirty
wash it with water and dry well in shade an install back in place.

Deodorizer Filters

Remove the deodorizer filters behind the air filter and expose them in direct
sunlight for 2 hours. 
And then insert these filters into original position.

Gasoline

Powder

Removal of Filters

Two different methods to open the front panel based on types of air conditioner as below ; 
Type 1: 

Open the upside of the panel and lift it up as shown. The hooks of the panel will come off. Remove the
air filters. Then pull out the plasma filter

Type 2: 

Open the front panel as shown.
Then pull the filter tab slightly forward to remove the air filter.
After removing the air filter remove the plasma and deodorizer filter by slightly pulling forward.

After cleaning and drying well reinstall the filters in their original position.

Front panel

Panel hook

Plasma filter

Plasma filter

Front panel

Don't touch this plasma filter within 10 seconds after opening the inlet grille, it may cause an electric shock.

Содержание ARNU07GSEL1

Страница 1: ... Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm Models SE S3 Series Type ART COOL Mirror Type ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH ...

Страница 2: ...g tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to ensure that they d...

Страница 3: ...t to do Be sure to follow the instruction WARNING Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the p...

Страница 4: ...oduct Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not plug or unplug the power supply plug during operation There is risk of fire or electric shock Do not touch operate the product with wet hands There is risk of fire or electrical shock Do not place a heater ...

Страница 5: ...risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electri...

Страница 6: ... where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Take care to...

Страница 7: ...t malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury R...

Страница 8: ...recision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit first make sure that the power and br...

Страница 9: ... the setting temperature and operation mode Cooling heating auto operation dehumidification mode Lights up during defrost mode or hot start operation Heat pump model only Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowing out from unit In defrost mode unit stops heating operation for few minutes to remove formation of ice on the heat exchange...

Страница 10: ...button 6 ON OFF button 7 Fan operation 8 Operation mode selection button 9 Fan speed button 10 Horizontal Vertical air flow direction button option 11 Room temperature 12 Plasma button 13 Time reset button 14 Operation lamp Timer Program Hour Cancel 2ndF Week Holiday Set Clr Min RESET PLASMA ZONE 1 2 3 4 Operation unit No Func Humidify JET SLo AUTO AUTO SWING OPERATION FAN SPEED Program set SUB FU...

Страница 11: ... Button Used to set Sleep Mode Auto operation 11 Air Circulation Button Used to circulate the room air without cooling or heating 12 Room Temperature Button Used to set the desired horizontal airflow direction 13 Plasma optional Used to start or stop the plasma purification function 14 Horizontal Airflow Direction Control Button optional Used to set the desired horizontal airflow direction 15 Rese...

Страница 12: ...ilters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodorizer filters behind the air filter and expose them in direct sunlight for 2 hours And then insert these filters into original position Gasoline Powder Removal of Filters Two differen...

Страница 13: ...ll it in the indoor unit Refer to page 12 for cleaning it Check that the air inlet and outlet of the indoor outdoor unit are not blocked Check that the ground wire is connected correctly It may be connect to the indoor unit side Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air condi...

Страница 14: ...faint or no display at all Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed For a noise that sounds like water flowing This is the sound of freon flowing inside the air condit...

Отзывы: