background image

8

TABLE OF CONTENTS

ENGLISH

TABLE OF CONTENTS

2

TIPS FOR SAVING ENERGY

3

IMPORTANT SAFETY INSTRUCTIONS

9

BEFORE USE

9

Preparing for operation

9

Usage

9

Cleaning and maintenance

9

Service

9

Nomenclature

10

PRODUCT INTRODUCTION

10

Name of parts

11

Indoor unit controls and indicators

12

Wireless remote controller

13

Remote control preparation

14

OPERATING INSTRUCTIONS

14

Cooling Mode

14

Heating Mode

14

Airflow Setting

14

Fan Speed Setting

15

Power Cooling/Heating Mode

15

Fan Mode 

15

Simple Reservation 

16

Defrost Mode 

16

Child Lock Operation Function

17

Auto Dry Function

17

Auto Restart Operation

18

MAINTENANCE AND SERVICE

18

Indoor Unit

19

Operation Tips

20

Troubleshooting Tips! Save time and money!

20

Call the service immediately in the following situations

Содержание APNW50GT3E0

Страница 1: ...ER Please read this manual carefully before operating your set and retain it for future reference FLOOR STANDING Original instructions MFL67724521 Rev 00_031319 www lg com Copyright 2016 2019 LG Electronics Inc All Rights Reserved TÜRKÇE ...

Страница 2: ... tightly while you are operating the air conditioner Adjust the direction of the air flow vertically or horizontally to circulate indoor air Speed up the fan to cool or warm indoor air quickly in a short period of time Clean the air filter once every 2 weeks Dust and impurities collected in the air filter may block the air flow or weaken the cooling dehumidifying functions For your records Staple ...

Страница 3: ...e is intended to be used by expert or trained users in shops in light industry and on farms or for commercial use by lay persons WARNING It can result in serious injury or death when the directions are ignored CAUTION It can result in minor injury or product damage when the directions are ignored WARNING Installation or repairs by unqualified persons can result in hazards to you and others The inf...

Страница 4: ...stalling the product Sharp edges could cause injury Be especially careful of the case edges and the fins on the condenser and evaporator For installation always contact the dealer or an Authorized Service Center There is risk of fire electric shock explosion or injury Do not install the product on a defective installation stand It may cause injury accident or damage to the product Be sure the inst...

Страница 5: ...ssible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electric shock or product failure When the product is soaked flooded or submerged contact an Authoriz...

Страница 6: ...ly on the condenser and evaporator fins could cause product malfunction or inefficient operation Operation Do not expose the skin directly to cool air for long periods of time Don t sit in the draft This could harm to your health Do not use the product for special purposes such as preserving foods works of art etc It is a consumer air conditioner not a precision refrigeration system There is risk ...

Страница 7: ...areful and avoid personal injury Replace all the batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of batteries There is risk of fire or explosion Do not recharge or disassemble the batteries Do not dispose of batteries in the fire They may burn or explode If the liquid from the batteries gets onto your skin or clothes wash it well w...

Страница 8: ... 12 Wireless remote controller 13 Remote control preparation 14 OPERATING INSTRUCTIONS 14 Cooling Mode 14 Heating Mode 14 Airflow Setting 14 Fan Speed Setting 15 Power Cooling Heating Mode 15 Fan Mode 15 Simple Reservation 16 Defrost Mode 16 Child Lock Operation Function 17 Auto Dry Function 17 Auto Restart Operation 18 MAINTENANCE AND SERVICE 18 Indoor Unit 19 Operation Tips 20 Troubleshooting Ti...

Страница 9: ...he metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock When cleaning the unit first make sure that the power and breaker are turned off The fan rotates at a very high speed during operation There is a possibility of inj...

Страница 10: ...DUCT INTRODUCTION ENGLISH Name of parts Indoor unit 1 Left Right Airflow Control Louver 2 Up Down Airflow Control Louver 3 Display Panel 4 Air filter 5 Air Inlet 6 Control Box 1 4 2 3 6 5 PRODUCT INTRODUCTION ...

Страница 11: ...icators Heat Pump 1 Timer 2 Defrosting operation lamp 3 Cooling operation lamp 4 Heating operation lamp 5 Room temp Set temp display 6 Indoor fan speed lamp 7 Start Stop button 8 Operation mode selection button 9 Room temperature setting button 10 Indoor fan speed button 11 Signal receptor ...

Страница 12: ...scription 1 r Remote controller operation lamp 2 Power ON OFF button Operation will start when this button is pressed and stop when the button is pressed again 3 4 FAN SPD Indoor fan speed button To select the desired fan speed 4 Temperature setting button 5 A Cooling button 6 B Heating button 7 Auto dry button If setting this function evaporator will be automatically dried before turning off the ...

Страница 13: ...erent from standard dry cells in shape dimensions and performance Change the batteries with a new one if the remote control does not work properly after using for an extended period of time CAUTION When not using remote controller for a long time flowing of dry cell liquid may cause the failure of product therefore remove all dry cells When replacing dry cell AAA replace two of them all with new o...

Страница 14: ...l 1 Press button to turn on the indoor 2 Press J button and the louvers will swing left and right 3 Press J button again to set the vertical louver at the desired airflow direction Airflow Setting Table Fan Speed Setting 1 Press button to turn on the indoor 2 Press button to select fan speed You can select the fan speed in four steps Low Mid High Super High Each time the button is pressed the fan ...

Страница 15: ...mp room temperature lamp and fan speed lamp of its display panel 1 Press button to turn on the indoor unit 2 Press button on remote controller to circulate indoor air When canceling operation press button once more During fan mode outdoor fan and compressor will not be operated During fan mode indoor unit turns on the fan speed lamp and room temperature lamp of its display panel Simple Reservation...

Страница 16: ... X button on remote control 2 During child lock operation Whenever you press any button on display panel it will immediately display CL which means display panel is locked All the button on the indoor unit display panel will not work But the button on the remote controller will be operated 3 Press the and high simultaneously for 3 seconds again The unit will respond with beep child lock operation ...

Страница 17: ...conds If manipulating remote control press button The indoor unit will respond with beep twice and Auto dry function will be removed Auto Restart Operation When power is supplied again after unit operation has been stopped because of interruption of power supply due to outage or other causes auto re operation will be performed by remembering previous setting When power is supplied outdoor unit ope...

Страница 18: ...mage the surfaces of the air conditioner Filter Cleaning Please clean it once in a week 1 Remove the Air filters Take hold of the tab and pull slightly forward to remove the filter 2 Clean dirt from the air filter using a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 40 C or more is used it may be deformed 3 After washing w...

Страница 19: ... windows are kept closed it is a good idea to open them and ventilate the room now and then When air conditioner is not going to be used for a long time 1 Operate the air conditioner at the following settings for 2 to 3 hours Type of operation Fan operation mode This will dry out the internal mechanisms Helpful information The air filters and your electiric bill If the air filters become clogged w...

Страница 20: ...ector of the mechanism Wait about three minutes and operation will begin Does not cool or heat effectively Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the temperature been set incorrectly Are the indoor unit s air inlet or outlet vents obstructed The air conditioner...

Страница 21: ...a Mahallesi Piyalepaşa Bulvarı No 73 Ortadoğu Plaza Kat 7 34384 Okmeydanı Şişli İstanbul Tel 0 212 314 52 52 Faks 0 212 222 61 44 ÜRETİCİ FİRMA LG Electronics Inc Changwon 2nd factory 84 Wanam ro Seongsan gu Changwon si Gyeongsangnam do KOREA www lg com ...

Отзывы: