background image

LG Water Cooled Package
Air Conditioner

OWNER'S MANUAL

LG

MODELS: AKWW0243AA0 AKWW0243YA0

AKWW0183AA0 AKWW0183YA0
AKWW0123AA0 AKWW0123YA0
AKWW0093AA0 AKWW0093YA0

IMPORTANT

• Please read this owner's manual carefully and thoroughly 

before installing and operating your room air conditioner.

• Please retain this owner's manual for future reference after 

reading it  thoroughly.

website  http://www.lgservice.com

ENGLISH

FRANÇAIS

ESPAÑOL

Содержание AKWW0093AA0

Страница 1: ...0 AKWW0123AA0 AKWW0123YA0 AKWW0093AA0 AKWW0093YA0 IMPORTANT Please read this owner s manual carefully and thoroughly before installing and operating your room air conditioner Please retain this owner s manual for future reference after reading it thoroughly website http www lgservice com ENGLISH FRANÇAIS ESPAÑOL ...

Страница 2: ...in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be su...

Страница 3: ...usness is classified by the following indications Meanings of symbols used in this manual are as shown below This symbol indicates the possibility of death or serious injury This symbol indicates the possibility of injury or damage to properties only Be sure not to do Be sure to follow the instruction Installation Do not place the power cord near a heater It may cause fire and electric shock Do no...

Страница 4: ...unspecified power cord It will cause electric shock or fire Do not modify power cord length It will cause electric shock or fire due to heat generation Always plug into a grounded outlet No grounding may cause electric shock See Installation Manual Unplug the unit if strange sounds odors or smoke come from it Otherwise it may cause fire and electric shock accident Do not operate with wet hands or ...

Страница 5: ...use explosion fire and burn Never touch the metal parts of the unit when removing the filter They are sharp and may cause injury Do not block the inlet or outlet It may cause failure of appliance or accident Be cautious not to touch the sharp edges when installing It may cause injury Turn off the main power switch when not using it for a long time Prevent accidental startup and the possibility of ...

Страница 6: ...igh speed during operation it may cause injury Do not put a pet or house plant where it will be exposed to direct air flow This could injure the pet or plant Do not use this appliance for special purposes such as pets foods precision machinery or objects of art It is an air conditioner not a precision refrigeration system Always insert the filter securely Clean it every two weeks Operation without...

Страница 7: ...d special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to clean inside the air conditioner Exposure to water can destroy the insulation leading to possible electric shock 3 When cleaning the unit fi...

Страница 8: ...e harm to the air conditioner This symbol indicates special notes NOTICE Features Introduction Symbols used in this Manual Valve Regulator Valve Solenoid Box Control Heat exchanger Water In Water Out Discharge Air Indoor Inlet Air Return Panel Grille Discharge AKWW0243AA0 AKWW0243YA0 AKWW0183AA0 AKWW0183YA0 AKWW0123AA0 AKWW0123YA0 AKWW0093AA0 AKWW0093YA0 ...

Страница 9: ... Is vibration isolation provided i e unit isolation pad hose kits Is unit serviceable See clearance specifications Are the low high side pressure temperature caps secure and in place Are all the unit access panels secure and in place Is the thermostat in the OFF position Is the water flow established and circulating through all the units Is the duct work if required correctly sized run taped insul...

Страница 10: ...ult of bad water the heat exchanger will have to be back flushed and cleaned with a chemical that will remove the scale This service should be performed by an experienced service person Hazardous Chemicals Coil cleaning agents can be either acidic or highly alkaline Handle chemical carefully Proper handling should include goggles or face shield chemical resistant gloves boots apron or suit as requ...

Страница 11: ...ry Fan Defrost Preheat Out door Slo Lo Med Hi Po Room Temp Total on Central Run 1 2 3 4 5 Each function will be shown on the display panel for three second or so when the power is applied at first 1 Operation Display Panel 2 On Off Function 3 Fan Speed Button 4 Temperature Control Button 5 Mode Selection Check Button ...

Страница 12: ...ma function 2Press the temperature button and set the desired temperature lower than the current room temperature 64 86 F If the desired temperature is set higher than the current room temperature the cooling function will not begin and just the blowing operation will continue 3If you press the mode button during the operation the operation mode will be changed in the order of cooling heating dry ...

Страница 13: ... higher than the current room temperature 64 86 F If the desired temperature is set lower than the current room temperature the heating function will not begin 3If you press the mode button during the operation the operation mode will be changed in the order of cooling heating dry dehumidification fan and auto operation 4If you press On Off button again the heating operation will stop What is the ...

Страница 14: ...ature is lower than the desired temperature Heating Operation starts For Heat Pump Models only When the room temperature is higher than the desired temperature Cooling Operation starts 3If you press the mode button during the operation the operation mode will be changed in the order of cooling heating dry dehumidification fan and auto operation The cooling only model will show AI on the temperatur...

Страница 15: ...nd air conditioning effect Temperature control is not available during the dry operation 1Press the On Off button on the remote controller Plasma function is always operating for working if product has plasma function 2Set the unit to fan operation by pressing the mode button 3When the fan is selected Fn will be displayed on the display panel 4 Fan operation does not give cold air but just the fan...

Страница 16: ... in Heating Dry Fan Auto Operation Hi Med Lo 1Select the proper fan speed which you want by pressing the fan speed button on the remote controller If you press the fan button the speed of the fan will change in the order of Low Medium Hi Power The initial fan speed is Hi If the product is not compatible with the Fan speed control it will not function as per your selection You can easily control th...

Страница 17: ...which the remote controller is located on Indoor Temperature Display Out door Room Temp Total on Central Run Defrost Preheat PQRCUCA0 FAN SPEED MODE 1You can use the child lock function by pressing both temperature increasing button and fan speed button for three seconds In the initial setting of the child lock function CL will be displayed on the display panel and then it will come back to the or...

Страница 18: ...ed correctly It may be connect to the indoor unit side Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the d...

Страница 19: ... occurs when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the setting temperature been set incorrectly Are the indoor...

Страница 20: ...20 Water Cooled Package Air Conditioner Memo ...

Страница 21: ...P No MFL30215204 Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...

Отзывы: