INSTALLATION OF INDOOR
ENGLISH
9
Wiring Connection
Connect the wires to the terminals on the
control board individually according to the out-
door unit connection.
- Ensure that the color of the wires of outdoor
unit and the terminal No. are the same as
those of indoor unit respectively.
- Insert the set anchor and washer onto the
suspension bolts for locking the suspension
bolts on the ceiling.
- Mount the suspension bolts to the set an-
chor firmly.
- Secure the installation plates onto the sus-
pension bolts (adjust level roughly) using
nuts, washers and spring washers.
1 Set anchor
Old building
New building
2 Plate washer
3 Spring washer
4 Nut
5 Suspension
bolts
CAUTION
Tighten the nut and bolt to prevent unit
falling.
!
CAUTION
The Power cord connected to the unit
should be selected according to the fol-
lowing specifications. (Cable type CV ap-
proved by IEC 60502-1)
!
Terminal
B
lock
Indoor
Terminal
B
lock
Indoor
1(L)
2(N)
3
Outdoor unit
Indoor unit
Terminal
B
lock outdoor
1(L)
2(N)
3
20mm
GN/
YL
NORMAL
CROSS-SECTIONAL
AREA 2.5mm
2
WARNING
Make sure that the screws of the termi-
nal are free from looseness.
!
Indoor Unit Installation
- Select and mark the position for fixing bolts.
- Drill the hole for set anchor on the face of
ceiling.
Содержание ABNQ18GL2A1