- 2 -
Copyright ©2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
1. Specification
Running Current
Cooling/Heating
A
Starting Current
Cooling/Heating
A
Power Supply
Ø,V,Hz
Power Supply Cable (Includes earth)
No.* mm
2
Interunit Cable (Includes earth)
No.* mm
2
Compressor Type
Quantity
Model
Motor Input
kw
Oil Charge
cc
Oil Type
Refrigerant Charge*
g(oz)
Type
Control
Heat exchnager
Tube Size (OD)
mm (inch)
Fins per inch
No.ofRows&Column/No.
Fan motor
Model
Output W
Capacitor µF/Vac
Fan Type
No. Used / Diameter
EA/mm (inch)
Discharge
Side / Top
Air Circulation
CMM(CFM)
Noise Level(H/L)
Sound Press,1m
dB(A)±3
Defrosting
SVC Valve
Liquid
mm (inch)
Gas mm
(inch)
Dimensions W*H*D
mm
(inch)
Net Weight (Outdoor)
kg(lbs)
Max. Piping Length/Elevation
m
Additional Refrigerant Charge (Over 7.5m)
g/m
Operation rating
Rang cooling
°C
outdoor
Heating
°C
Models
AUUH246D [UU24 UED]
11.4/12.6
1,220~240,50
3*2.5
4*0.75
Rotary
1
GP290PAC
2.50
1,130
FVC68D (PVE)
1950(68.9)
R410A
EEV
7.0 (0.276)
18
2R,36C
IC28640LG28P
67
6/370
Propeller
1/460 (18.1)
Side Discharge
58(2048)
52
Reversing cycle
9.52(3/8)
15.88 (5/8 )
870*808*320(34.3*31.8*12.6)
60(132.2)
40/30
45
-5~43
-10~24
Note:
1. Capacities are based on the following conditions:
Cooling: - Indoor Temperature 27°C(80.6°F) DB/19°C(66.2°F) WB
- Outdoor Temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: - Indoor Temperature 20°C(68°F) DB/15°C(59°F) WB
- Outdoor Temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping Length - Interconnecting Piping Length 7.5m
- Level Difference of Zero
2. Wiring cable size must comply with the applicable local and national
code.
3. The specification may be subject to change without notic for purpose of
improvement.
Indoor Unit
ATNH24GPLED [UT24 NPD]
Nominal Capacity
Cooling
kW
Btu/h
Heating
kW
Btu/h
Nominal Input
Cooling
kW
Heating
kW
Indoor Unit
Nominal Capacity
Cooling
kW
Btu/h
Heating
kW
Btu/h
Nominal Input
Cooling
kW
Heating
kW
Indoor Unit
Nominal Capacity
Cooling
kW
Btu/h
Heating
kW
Btu/h
Nominal Input
Cooling
kW
Heating
kW
Indoor Unit
Outdoor Unit
7.00
23,885
7.5
25,592
2.49
2.6
ABNH246HLAD [UB24 NHD]
6.50
22,180
7.40
25,250
2.49
2.6
AVNH246BLAD [UV24 NBD]
6.50
22,180
7.30
24,910
2.49
2.6
Содержание ABNH246HLAD
Страница 7: ...P NO MFL37468320 JANUARY 2008 ...