8
INSTALLATION OF INDOOR, OUTDOOR UNIT
ENGLISH
Read completely, then follow step by step.
Select the best location
1
Do not have any heat or steam near the
unit.
2
Select a place where there are no obstacles
in front of the unit.
3
Make sure that condensation drainage can
be conveniently routed away.
4
Do not install near a doorway.
5
Ensure the spaces indicated by arrows from
the wall, ceiling, fence or other obstacles.
6
Use a stud finder to locate studs to prevent
unnecessary damage to the wall.
1
If an awning is built over the unit to prevent
direct sunlight or rain exposure, make sure
that heat radiation from the condenser is
not restricted.
2
Ensure that the spaces indicated by arrows
around front, back and side of the unit.
3
Do not place animals and plants in the path
of the warm air.
4
Take the air conditioner weight into account
and select a place where noise and
vibration are minimum.
5
Select a place so that the warm air and
noise from the air conditioner do not
disturb neighbors.
If the outdoor unit is installed on a roof
structure, be sure to level the unit. Ensure the
roof structure and anchoring method are
adequate for the unit location. Consult local
codes regarding rooftop mounting.
Install the indoor unit on the wall where
the height from the floors more than 2.3
meters. (ART COOL Type Only 1.5 m)
CAUTION
!
More than 20 cm
More than
10 cm
More than 2.3 m
More than
10 cm
More than 20 cm
More than
10 cm
More than 2.3 m
More than
10 cm
More than 20 cm
More
than 50 cm
More than 1.5 m
More
than 50 cm
More than 20 cm
More than
10 cm
More than 2.3 m
More than
10 cm
more than
70 cm
more than
30 cm
more than
30 cm
more than
60 cm
more than 60 cm
more than
70 cm
more than
30 cm
more than 60 cm
more than
30 cm
more than
60 cm
Indoor unit
Outdoor unit
Rooftop Installations
INSTALLATION OF INDOOR, OUTDOOR UNIT
Содержание A7UW40GFA0