2. Function Table

Note :

O : Applied     X : Not applied     - : No relation
Option : Model name & price are different according to options, and assembled in factory with main unit.
Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package

H

: These safty switcher are standard or optional features defending on region & country

Defrost / Deicing
High pressure switch
Low pressure switch

Reliability

Phase protection
Restart delay (3-minutes)
Self diagnosis
Soft start
Test function

Convenience

Auto operation(Artificial intelligence)
Auto restart operation

CAC network

Network soluation(LGAP)

function

PDI(Power Distribution Indicator)
PI485

Special  function kit

Low ambient operation

Others

Thermistor

Function

Category

A2UW183FA2 (LMU187HV)

O

X

O

X

O
O
O
O
O
O
O

PQNUD1S00

PMNFP14A0

O (Program logic)

-

- 3 -

Copyright ©2010 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

Содержание A2UW183FA2

Страница 1: ...oner SVC MANUAL Exploded View MODEL A2UW183FA2 LMU187HV CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Страница 2: ... A 1 5 5 2 10 8 Heating A 1 5 6 0 11 3 Starting Current Cooling Heating A Power Supply Ø V Hz 1 208 230 60 Power Supply Cable outdoor No x AWG 3 x 12 transmission cable outdoor to indoor No x AWG 4 x 18 Including Earth Dimensions W x H x D mm 870 x 808 x 320 inch 34 1 4 x 31 13 16 x 12 19 32 Net Weight kg lbs 56 123 5 Net Weight Package kg lbs 60 132 Compressor Type Twin Rotary Qty x Model 1 x GKT...

Страница 3: ...st Deicing High pressure switch Low pressure switch Reliability Phase protection Restart delay 3 minutes Self diagnosis Soft start Test function Convenience Auto operation Artificial intelligence Auto restart operation CAC network Network soluation LGAP function PDI Power Distribution Indicator PI485 Special function kit Low ambient operation Others Thermistor Function Category A2UW183FA2 LMU187HV...

Страница 4: ...essure S W Compressor Accumlator Heat TH3 EEV A EEV B Liquid Side COOLING HEATING TH4 Gas Side OUTDOOR UNIT LOC Description PCB Connector Th1 Thermistor for discharge pipe temperature CN_TH3 Th2 Thermistor for suction pipe temperature CN_TH3 Th3 Thermistor for outdoor air temperature CN_TH2 Th4 Thermistor for condensing temperature CN_TH2 Note EEV Electronic Expansion Valve ...

Страница 5: ...lectronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 4 Wiring Diagrams CN_PRESS CN_4WAY PIPE LENGTH S W CN_PSC1 CN_PSC2 CN_TH3 CN_TH2 CN_FLASH CN_LGMV CN_EEV1 CN_COM CN_MOTOR CN_EEV2 ...

Страница 6: ...0 661400A 552200 661400B 552203B 552203A W4986 561410 W6631 435511B 649950 268711B 263230A 263230B W6640 AIR PIPE SUC DIS 552202 566000 550140 NOTE Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz Lgservice com Model Classification Description Part Number Lo...

Страница 7: ...P NO MFL63721204 NOVEMBER 2010 ...

Отзывы: