background image

- 2 -

Copyright ©2009 LG Electronics. Inc. All right reserved.
Only for training and service purposes

LGE Internal Use Only

1. Specification

Note :

1. Capacities are based on the following conditions:

Cooling: - Indoor Temperature 27°C(80.6°F) DB /19°C(66.2°F) WB

- Outdoor Temperature 35°C(95°F) DB /24°C(75.2°F) WB

Heating: - Indoor Temperature 20°C(68°F) DB / 15°C(59°F) WB

- Outdoor Temperature 7°C(44.6°F) DB / 6°C(42.8°F) WB

Piping Length - Interconnecting Piping Length 7.5m  

- Level Difference of Zero.

2. Due to our policy of innovation some specifications may be changed without notification.
3. At least two indoor units should be connected.
4. Wiring cable size must comply with the applicable local and national code.

Conversion Formula
kW

= Btu/h 

×

0.0002931

CFM = CMM 

×

35.3

Nominal Capacity

Cooling

kW

(Min~Rated~Max)

Btu/h

Heating

kW

Btu/h

Nominal Input

Cooling

kW

(Min~Rated~Max)

Heating

kW

Energy label
Testing Combination
Running Current

Cooling

A

Heating

A

Starting Current

(Cooling/Heating)

A

Power Supply

Ø / V / Hz

Power Supply Cable (outdoor)

No.* mm2

Power and transmission cable (outdoor to indoor)

No.* mm2

Power and transmission cable (BD to indoor)

No.* mm2

Dimensions

W*H*D

mm(inch)

Net Weight

kg(lbs)

Gross Weight

kg(lbs)

Max. Number of Connectable Indoor Units
Compressor #1

Type

Qty x Model

Motor Type

Oil Charge volume

cc

Oil Type

Refrigerant

Cycle A Charge (at 7.5m)

g(oz)

Type

Control

Heat Exchanger

Rows x Column x FPI

Defrosting Method

Fan

Capacitor

µF/Vac

Drive

Discharge direction

Side / Top

Air Flow Rate

CMM(CFM)

Noise Level(H/L)

Sound Pressure at 1m

dB(A)+3

Piping connections

Liquid(Cycle A)

mm(inch)

Gas(Cycle A)

mm(inch)

Max. Interunit

Total of Each Room

m

Piping Length

Main Piping

m

Max. Elevation

Indoor Unit~Outdoor Unit

m

Indoor Unit~Indoor Unit

m

1.35~4.69~5.13

4,600~16,000~17,500

1.41~5.27~5.71

4,800~18,000~19,500

0.4~1.38~1.83

0.39~1.31~1.73

A/A

CS09AQ NB0 * 2EA

1.6-6.13-8.04
1.7-5.88-7.51

8

1 / 220~240 / 50

3*2.5

4*0.75 (including earth)

-

770*545*288 (30.3*21.3*11.8 )

40(88.2)

42.5(93.5)

2

Rotary

1 x GKT141DAA

BLDC

570

FVC68D

1300(42.3)

R410A

EEV

2R x 24C x 18

Reversing cycle

-

Direct

Side

28.2(995)

50

6.35(1/4)*2EA
9.52(3/8)*2EA

30
20
15

7.5

A2UW166FA5

MU2M17[UL0]

Outdoor Unit

Содержание A2UW166FA5

Страница 1: ...ner SVC MANUAL Exploded View MODEL A2UW166FA5 MU2M17 UL0 CAUTION Before Servicing the unit read the safety precautions in General SVC manual Only for authorized service personnel Internal Use Only http biz lgservice com ...

Страница 2: ...pply Ø V Hz Power Supply Cable outdoor No mm2 Power and transmission cable outdoor to indoor No mm2 Power and transmission cable BD to indoor No mm2 Dimensions W H D mm inch Net Weight kg lbs Gross Weight kg lbs Max Number of Connectable Indoor Units Compressor 1 Type Qty x Model Motor Type Oil Charge volume cc Oil Type Refrigerant Cycle A Charge at 7 5m g oz Type Control Heat Exchanger Rows x Col...

Страница 3: ... by the corresponding model name supplied with separate package 2 List of Functions Defrost Deicing O High Pressure Switch X Low Pressure Switch X Phase protection X Restart Delay 3 minutes O Self Diagnosis O Soft Start O Test Function O Auto operation Artificial intelligence O Auto Restart Operation O Central control LGAP X PDI Power Distribution Indicator X PI485 X Low ambient operation Thermist...

Страница 4: ...V B 9 52 6 35 LEV 15RC D pipe Sensor Including strainer 1 6 500 1 6 500 1 6 500 1 6 500 1 6 600 Strainer GKT141DAA Inverter Sensor LOC Description PCB Connector TH1 Thermistor for discharge pipe temperature CN_TH2 TH2 Thermistor for suction pipe temperature CN_TH2 TH3 Thermistor for outdoor air temperature CN_TH1 TH4 Thermistor for condensing temperature CN_TH1 3 Piping Diagrams ...

Страница 5: ...09 LG Electronics Inc All right reserved Only for training and service purposes LGE Internal Use Only 4 Wiring Diagrams CN_COIL2 CN_COIL2 CN_4WAY CN_TH1 CN_TH2 CN_EEV1 CN_EEV2 CN_CENTRAL CN_LGMV CN_FLASH WRITER CN_COM ...

Страница 6: ...437211 237202 435301 430410 263230A W4986 554160 550140 261704 546810 554031 435312 137213B 559010 661400B 552113 552116 W6640 W6631 552202 435512 549610 552200B 552200B 552203B 552203A 561410 152503 Note Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request Please check the correct parts in View RPL Replacement Part List on GCSC GCSC Website http biz Lgs...

Страница 7: ...P NO MFL61921705 OCTOBER 2009 ...

Отзывы: