background image

Jet Cool/Heat Operation

NEO PLASMA Purification Operation (Optional)

AUTO CLEAN

During auto clean function, only START/STOP BUTTON, PLASMA BUTTON and AUTO CLEAN BUTTON
can be used.

NOTE

During auto clean function, moistures left in indoor units after cooling operation or healthy dehumidification
operation can be removed.

1. Press the AUTO CLEAN BUTTON to activate this function.
2. Now whenever the unit is turned off, the indoor fan is still running for about 30

minutes internally  without cooling or dehumidification operation. Also the louver is
closed.

3. This dries up any remains of  moisture & cleans the unit internally.
4. If you press AUTO CLEAN BUTTON again during operation, this function is

cancelled.

Auto Clean (Optional)

Jet cool function can be used to cool the room quickly in hot summer. When this

function is turned on, the air conditioner runs in cooling operation mode with super

high fan speed and 18°C setting temperature for 30 minutes for fast and effective
cooling.
Similarly, jet heat function (available only in some models) warms up the room quickly
by operating at super high fan speed and 30°C setting temperature for 60 minutes.

Plasma filter is a technology developed by LG to get rid of microscopic
contaminants in the intake air by generating a plasma of high charge electrons.
This plasma kills and destroys the contaminants completely to provide clean and
hygienic air.

You can activate this operation by pressing the JET COOL BUTTON.
To change from jet cool mode to high fan speed cooling mode, press the JET COOL BUTTON or
INIDOOR FAN SPEED SELECTOR BUTTON or the ROOM TERPERATURE SETTING BUTTON again.

• Jet cool function cannot be activated during heating or auto changeover operations.
• In case of Inverter, Art Cool and Art Cool Wide(non-Deluxe) model, you can use jet heat function by

pressing JET COOL BUTTON for heating operation.

• Art Cool and Art Cool Wide models close the side discharges during jet cool/heat operation, for strong

cooling and heating.

NOTE

Plasma purification can be started by pressing the PLASMA BUTTON on the remote controller. 
Repressing it will deactivate the operation.

This feature can be used in any operation mode and any fan speed can be used while
plasma filter is functioning. 

NOTE

12

Room Air Conditioner

Operating Instructions

Содержание A122CX NF0

Страница 1: ...CONDITIONER Please read this manual carefully before operating your set and retain it for future reference P NO 3828A20928G www lge com TYPE WALL MOUNTED ENGLISH ESPAÑOL A122CX NF0 A122CX UF0 A122CX NF1 A122CX UF1 MODELS ...

Страница 2: ...re that they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Outdoor Unit 7 D Operating I...

Страница 3: ...ecurely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an ...

Страница 4: ... failure If strange sounds smell or smoke comes from product Immediately turn the breaker off or disconnect the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repai...

Страница 5: ...used in the system If air enters the refrigerant system an excessively high pressure results causing equipment damage or injury If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ... Please see the information specific to your indoor unit type Product Introduction Product Introduction Signal Receptor Front Panel Air Discharge Air Intake Vents Air Outlet Vents Power Cord Connecting Wires Piping Drain Hose Base Plate Air Filter Plasma Filter Indoor Units Outdoor Unit ...

Страница 8: ...te controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth to clean them 3 In case some other appliances also get operated with remote control change their position or consult your serviceman 1 The signal receiver is inside the unit 2 Aim the remote controller towards ...

Страница 9: ...CEL BUTTON Used to set and to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON OPTIONAL For inverter type models 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON OPTIONAL Used to start or stop the plas...

Страница 10: ...heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SPEED SELECTOR BUTTON Each time the button is pres...

Страница 11: ... basically is heating or cooling function of the air conditioner But during this operation the controller changes the operation mode automatically to keep the temperature within 2 C with respect to the setting temperature In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel ho...

Страница 12: ...ms up the room quickly by operating at super high fan speed and 30 C setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air You can activate this operation by pressing the JET ...

Страница 13: ... OFF button is pressed If you want to stop operation re press the button ON OFF button Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan...

Страница 14: ... functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Start Stop button 2 Press 2nd F button and check if icon is on 3 Press the TIME SETTING BUTTONS until the desired time is set 4 Press the TIME SET CANCEL BUTTON Check the indicator for A M and P M NOTE 1 Make sure to set current time ...

Страница 15: ...bled by factory default setting but you can disable it by pressing the ON OFF button for 6 seconds The unit will beep twice and the indicator lamp 2 will blink 4 times To enable it press the button again for 6 seconds The unit will beep twice and the indicator lamp 1 will blink 4 times NOTE Air Circulation Mode This function is useful in the situation of power failure When power regains after a fa...

Страница 16: ...lter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodorizer filters behind the air filter and expose them in direct sunlight for 2 hours ...

Страница 17: ... off a protective tape attached at the mat 6 Place the picture photograph between the exited picture and mat Recommended size of a photo picture 450mm x 450mm 7 Cover mat and press down with hand s until contacting closely 8 Slide the photo graph drawing requested under both hanger parts as following and fix them Press the front panel lightly to close 9 Push both links of lower part of panel insid...

Страница 18: ...lectricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean ...

Страница 19: ...ill trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or turn ...

Страница 20: ...20 Room Air Conditioner Memo ...

Страница 21: ...LG ELECTRONICS MEXICO S A DE C V Sor Juana Ines de la Cruz No 555 San Lorenzo Tlalnepantla Estado de Mexico C P 54033 TEL 55 5321 1919 01800 3471919 ...

Отзывы: