background image

4

Room Air Conditioner

Safety Precautions

Indoor/outdoor wiring connections must  be
secured tightly and the cable should be routed
properly so that there is no force pulling the
cable from the connection terminals.

• Improper or loose connections can cause

heat  generation or fire.

Safely dispose off the packing materials. Like
screws, nails, batteries, broken things etc
after installation or svc and then tear away
and thraw away the plastic packaging bags.

• Children may play with them and cause

injury.

Make sure to check that the power cable
plug is not dirty, loose or broken  and
then only insert the plug completely.

• Dirty, loose or broken power plug can

cause electric shock or fire.

Be sure to check the refrigerant to the
used. Please read the label on the product.

• Incorrect refrigerant used can prevent the

normal operation of the unit.

Don't use a power cord, a plug  or a loose
socket which is damaged.

• Otherwise it  may cause a fire or electrical

shock.

Do not touch , operate, or repair  the
product with wet hands. Hold the plug by
hand when taking out 

• There is risk of electric shock  or fire.

Do not place a heater or other heating
appliances near the power cable.

• There is risk of fire and electric shock.

Do not allow water to run into electric parts.
Install the unit away from water sources.

• There is risk of fire, failure of the product, or

electric shock.

Do not store or use or even allow flammable
gas or combustibles near the product. 

• There is risk of fire.

Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.

• Oxygen deficiency could occur and hence

harm your health.

Do not open the front  grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.) 

• There is risk of physical injury, electric shock,

or product failure.

If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.

• There is risk of electric shock or fire.

Ventilate the product room  from time to
time when operating it together with a
stove, or heating element etc.

• Oxygen deficiency can occur and hence harm

your health.

Turn the main power off and unplug the
unit when cleaning or repairing the
product. 

• There is risk of electric shock.

When the product is not to  be used for a
long time, disconnect the power supply
plug or turn off the breaker.

• There is risk of product damage or failure, or

unintended operation.

Take care to ensure that nobody especially
kids could step on or fall onto the outdoor unit. 

• This could result in personal injury and

product damage. 

Take care to ensure that power cable could not
be pulled out or damaged during operation.

• There is risk of fire or electric shock.

Do not place ANYTHING  on the power
cable.

• There is risk of fire or electric shock.

Do not plug or unplug the power supply
plug to turn the unit ON/OFF .

• There is risk of fire or electric shock.

When flammable gas leaks, turn off the
gas and open a window for ventilation
before turn the product on. 

• Do not use the telephone or turn switches on

or off. There is risk of explosion or fire.

For inner cleaning, contact an Authorized
Service Center or a dealer. 
Do not use harsh detergent that causes
corrosion or damage on the unit.

• Harsh detergent may also cause failure of

product, fire, or electronic shock.

Two or more people must lift and
transport the product. 

• Avoid personal injury. 

Do not install the product where it will be
exposed to sea wind (salt spray) directly.

• It may cause corrosion on the product. 

Install the drain hose to ensure that the
condensed  water is drained away properly. 

• A bad connection may cause water leakage.

Keep level even when installing the
product.

• To avoid vibration or noise.

Do not install the product where the noise
or hot air from the outdoor unit could
damage or  disturb the neighborhoods.

• It may cause a problem for your neighbors

and hence dispute.

Always check for gas (refrigerant)
leakage after installation or repair of
product.

• Low refrigerant levels may cause failure of

product.

Содержание A07LHD

Страница 1: ...et and retain it for future reference The equipment complies with requirements of the Technical Regulation in terms of restrictions for the use of certain dangerous substances in electrical and electronic equipment P NO MFL41604501_v1 www lg com KZ O 02 0561 ENGLISH êìëëäàâ üáõä ìäêÄ çëúäÄ ...

Страница 2: ...at they do not play with the air conditioner When the power cord is to be replaced replacement work shall be performed by authorized personnel only using only genuine replacement parts A Safety Precautions 3 B Electrical Safety 6 Temporary Use of an Adapter 6 Temporary Use of an Extension Cord 6 Symbols used in this Manual 6 C Product Introduction 7 Indoor Units 7 Operation Indication Lamps 8 Outd...

Страница 3: ...ecurely There is risk of fire or electric shock due to dust water etc Use the correctly rated breaker or fuse There is risk of fire or electric shock Do not modify or extend the power cable If the power cable or cord has scrathes or skin peeled off or deteriorated then it must be replaced There is risk of fire or electric shock For installation removal or reinstall always contact the dealer or an ...

Страница 4: ... the power supply cable There is risk of electric shock or fire Ventilate the product room from time to time when operating it together with a stove or heating element etc Oxygen deficiency can occur and hence harm your health Turn the main power off and unplug the unit when cleaning or repairing the product There is risk of electric shock When the product is not to be used for a long time disconn...

Страница 5: ...y If the refrigerant gas leaks during the installation ventilate the area immediately Otherwise it can be harmfull for your health Dismantling the unit treatment of the refrigerant oil and eventual parts should be done in accordance with local and national standards Replace the all batteries in the remote control with new ones of the same type Do not mix old and new batteries or different types of...

Страница 6: ...nuine adapter available from most local hardware stores Ensure that the large slot in the adapter is aligned with the large slot in the receptacle for a proper polarity connection To disconnect the power cord from the adapter use one hand on each to avoid damaging the ground terminal Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage Never use the applia...

Страница 7: ...ide Display panel LED indicators Signal receiver Front panel Air discharge Power cord Plasma filter Air filter Signal receiver Front panel Air inlet Air discharge Power cord Plasma filter Air filter Air inlet Plasma filter Optional Air filter Air outlet Front grille ON OFF button Signal receiver Grille tab Flap Horizontal blade Louvers Vertical blades Operation lamp Signal Receiver ON OFF button A...

Страница 8: ...de Power Display Indicates the setting temperature and operation mode SUB DISPLAY OPTIONAL Blue Plasma Green Auto clean Orange Ion Lights up during defrost mode or hot start operation Heat pump model only Lights up during outdoor unit operation Cooling model only Outdoor unit operation OUT DOOR Hot start operation Stops the indoor fan in heating operation for minutes to prevent cold air from blowi...

Страница 9: ...tarts fading replace both of the batteries 4 Use 2 AAA 1 5volt batteries NOTE 1 Choose a suitable place where its safe easy to reach 2 Fix the holder to wall etc with the supplied screws firmly 3 Slide the remote controller inside the holder 1 Remote controller should never be exposed to direct sunlight 2 Signal transmitter receiver should always be clean for proper communication Use a soft cloth ...

Страница 10: ...to cancel the timer operation 10 SLEEP MODE AUTO BUTTON Used to set sleep mode auto operation 11 AIR CIRCULATION BUTTON Used to circulate the room air without cooling or heating ENERGY SAVING COOLING MODE BUTTON OPTIONAL For inverter type models 12 ROOM TEMPERATURE CHECKING BUTTON Used to check the room temperature 13 PLASMA BUTTON OPTIONAL Used to start or stop the plasma purification or plasma i...

Страница 11: ... Auto Changeover Heat Pump Model For cooling or heating operation set the desired indoor temperature by pressing the ROOM TEMPERATURE SETTING BUTTONS For cooling the temperature can be set within 18 C 30 C and for heating the temperature range is 16 C 30 C Set the fan speed with the remote controller You can select the fan speed in four steps low medium high and CHAOS by pressing the INDOOR FAN SP...

Страница 12: ... cooling function of the air conditioner But during this operation the controller changes the operation mode automatically to keep the temperature within 2 C with respect to the setting temperature Operating Instructions In this operation mode the actual setting temperature and the fan speed are automatically set by the electronic control logic based on the current room temperature If you feel hot...

Страница 13: ...per high fan speed and 30 C setting temperature for 60 minutes Plasma filter is a technology developed by LG to get rid of microscopic contaminants in the intake air by generating a plasma of high charge electrons This plasma kills and destroys the contaminants completely to provide clean and hygienic air Ionizer generates the ion for healthy Ion stabilizes user s mind and it does good to respirat...

Страница 14: ... If you want to stop operation re press the button ON OFF button Heat pump Model Cooling Model Room Temp 24 C 21 C Room Temp 24 C Room Temp 21 C Operating mode Cooling Cooling Healthy Dehumidification Heating Indoor FAN Speed High High High High Setting Temperature 22 C 22 C 23 C 24 C Test operation During the TEST OPERATION the unit operates in cooling mode at high speed fan regardless of room te...

Страница 15: ...y dehumidification mode The setting temperature will rise automatically two times by 1 C over next consecutive 30 minutes 2 C in 1 hour for a comfortable sleep Now this will be the final setting temperature as long as sleep mode is functioning NOTE 1 Time can be set only when you press the RESET BUTTON Having replacing the batteries you should press the RESET BUTTON to reset the time Press the Sta...

Страница 16: ...d at the same time to make the human body feel most comfortable as if enjoying natural breeze Always use the remote controller to adjust the up and down air flow direction Manually moving the vertical air flow direction louver by hand could damage the mechanism When the unit is shut off the up down airflow direction louver will close the air outlet vent of the system NOTE CHAOS Air economizes powe...

Страница 17: ...lasma filters behind the air filter should be checked and cleaned once in every 3 months or more often if necessary To remove the filters see the self explanatory diagrams for each model type Clean the filters with a vacuum cleaner If it is dirty wash it with water and dry well in shade an install back in place Deodorizer Filters Remove the deodorizer filters behind the air filter and expose them ...

Страница 18: ...g well reinstall the filters in their original position Front panel Panel hook Plasma filter Plasma filter Front panel 5 Standard Split Type Two different methods to open the front panel based on types of air conditioner as below Type 1 Open the front panel as shown Then pull the filter tab slightly forward to remove the air filter After removing the air filter remove the plasma and deodorizer fil...

Страница 19: ...air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in the room Make sure that the doors and windows are shut thight Avoid opening doors and windows as much as possible to keep the cool air in the room Clean the air filter regularly Blockages in the air filter reduce the airflow and lower cooling and...

Страница 20: ...er will trip Make sure there are no curtains blinds or furniture blocking the front of the air conditioner Clean the filter at least every 2 weeks See the Maintenance and Service section When the air conditioner is first turned on you need to allow time for the room to cool down Check for open furnace floor registers and cold air returns Make sure they are correct Check and remove such source or t...

Страница 21: ......

Отзывы: