V
Adj. condition and cautionary items
(1) Lighting condition in surrounding area
Surrounding lighting should be lower than 10 lux. Try
to isolate adj. area into dark surrounding.
(2) Probe location
- PDP : Color Analyzer (CA-100, CA-100+, CA210)
probe should be firmly attached to the Module
- LCD : Color Analyzer (CA-210) probe should be within
10cm and perpendicular of the module surface
(80°~ 100°)
- In case of LCD, B/L on should be checked using no
signal or Full white Pattern
8-7. Reference (White Balance adj.
coordinate and color temperature)
O
Standard color coordinate and temperature using CS-1000
O
Luminance: Full white 216 Gray
O
Standard color coordinate and temperature using CA-210(CH
10)
- Gain color coordinate
O
Pattern : Full white 216 Gray
9. 3D Function Test
9-1. 3D Pattern Inspection
(Pattern Generator MSHG-600 or MSPG-6100, HDMI mode
NO. 872 , pattern No. 83)
(1) Please input 3D test pattern like below
(2) When 3D entrance OSD is automatically displayed, Push
the OK key
(3) When took off 3D shutter glasses, Check whether viewing
the pattern like below picture)
9-2. 2D TO 3D CONVERT INSPECTION
(1) Input Combination Pattern like (Fig.1) in HDMI Input
(2) Enter the Swap Button(Yellow Color)
Check the separated line in the SET
* When you enter the swap button. Depth value is set to
Maximum value(20) automatically Worker has to enter the
ETC Key Before using the swap button
9-3. RF Glasses , 3D RF Emitter Check
* Power Only Mode
* MSHG-600 or MSPG-6100
- 10 -
LGE Internal Use Only
Copyright ©2011 LG Electronics Inc. All rights reserved.