- 14 -
LGE Internal Use Only
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
**(normal line) Model : For LGD (LB56xx, LB55xx)
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
286
289
313
329
1
0-2
281
285
296
304
323
344
2
3-5
280
284
295
303
322
343
3
6-9
279
282
294
301
321
341
4
10-19
277
279
292
288
319
338
5
20-35
275
275
290
294
317
334
6
36-49
273
273
288
292
315
332
7
50-79
272
272
287
291
314
331
8
80-119
271
270
286
289
313
329
9
Over 120
271
270
286
289
313
329
**(aging chamber) Model : For LGD (LB56xx, LB55xx)
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
286
289
313
329
1
0-5
280
285
295
304
319
340
2
6-10
276
280
291
299
315
335
3
11-20
272
275
287
294
311
330
4
21-30
269
272
284
291
308
327
5
31-40
267
268
282
287
306
323
6
41-50
266
265
281
284
305
320
7
51-80
265
263
280
282
304
318
8
81-119
264
261
279
280
303
316
9
Over 120
264
260
279
279
303
315
** For INX,AUO,SHARP,CSOT Module.( In the case of , the color
temperature spec of cool mode is 13000K)
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
spec
271
270
286
289
313
329
329
target
276
277
291
296
318
336
340
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
(3) Using DFT(Auto)
※
PC (for communication through RS-232C) -> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
ITEM
DATA(Area Number)
AREA
AREA OPTION1
0
USA
1
CANADA
2
MEXICO
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model
Module
Tool
option1
Tool
option2
Tool
option3
Tool
option4
32LB550B-UZ
LGD
784
13314
41036
20544
32LB560B-UZ
SHARP
13074
9218
41036
20544
32LB550B-UZ
SHARP
13074
13314
41036
20544
42LB5500-UZ
LGD
1552
5126
41036
24640
42LB5500-UZ
AUO
9744
5126
41036
24640
42LB5600-UZ
LGD
1552
1030
41036
24640
42LB5600-UZ
AUO
9744
1030
41036
24640
39LB5600-UZ
INX
17682
1030
41036
24640
49LB5500-UZ
LGD
2064
5126
41036
24640
55LB5500-UZ
LGD
2576
5126
41036
24640
55LB5500-UZ
BOE
23058
5126
41036
24640
32LB550B-UZ
BOE
21266
13314
41036
24640
32LB5600-UZ
LGD
784
1026
41036
24640
32LB560B-UZ
LGD
784
9218
41036
20544
※
Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode
Содержание 55LB5500