Owner’s Manual 33
ENGLISH
External Control Device Setup
Transmission
* [Command 1]: k, j, m,d
* [Command 2]: To control Plasma Monitor set.
* [Set ID]: You can adjust the set ID to choose desired moni-
tor ID number in Special menu. Adjustment range
is 1 ~ 99. When selecting Set ID ‘0’, every con-
nected Plasma Monitor set is controlled. Set ID is
indicated as decimal (1~99) on menu and as
Hexa decimal (0x0~0x63) on transmission/receiv-
ing protocol.
* [DATA]: To transmit command data.
Transmit ‘FF’ data to read status of command.
* [Cr]: Carriage Return
ASCII code ‘0x0D’
* [ ]: ASCII code ‘space (0x20)’
[Command1][Command2][ ][Set ID][ ][Data][Cr]
OK Acknowledgement
* The Monitor transmits ACK (acknowledgement) based on
this format when receiving normal data. At this time, if the
data is data read mode, it indicates present status data. If
the data is data write mode, it returns the data of the PC
computer.
[Command2][ ][Set ID][ ][OK][Data][x]
Error Acknowledgement
* * If there is error, it returns NG
[Command2][ ][Set ID][ ][NG][x]
T
T
ransmission / Receiving Protocol
ransmission / Receiving Protocol
• Baud rate : 9600 bps (UART)
• Data length : 8 bits
• Parity : None
• Stop bit : 1 bit
• Communication code : ASCII code
Communication Parameters
Communication Parameters
01. Power
k
a
0 ~ 1
02. Input Select
k
b
1 ~ 9
03. Aspect Ratio
k
c
0 ~ 3
04. Screen Mute
k
d
0 ~ 1
05. Volume Mute
k
e
0 ~ 1
06. Volume Control
k
f
0 ~ 64
07. Contrast
k
g
0 ~ 64
08. Brightness
k
h
0 ~ 64
09. Color
k
i
0 ~ 64
10. Tint
k
j
0 ~ 64
11. Sharpness
k
k
0 ~ 64
12. OSD Select
k
l
0 ~ 1
13. Remote Control Lock Mode k
m
0 ~ 1
14. Balance
k
n
0 ~ 3
15. Color Temperature
k
q
0 ~ 3
16. Abnomal state
k
r
0 ~ 64
17. ISM mode
k
s
0 ~ 64
18. Auto configuration
k
t
0 ~ 64
19. Key
k
u
0 ~ 3
20. Tile Mode
k
v
0 ~ 14
21. Tile H Size
k
w
0 ~ 14
22. Tile V Size
k
$
0 ~ 14
23. Tile ID Set
k
y
1 ~ 9
24. Elapsed time return
k
z
0 ~ a
25. Temperature value
j
p
0 ~ 3
26. Lamp fault check
j
q
0 ~ 1
COMMAND 1 COMMAND 2
DATA
(Hexadecimal)
Command Reference List
Command Reference List
PICTURE
SOUND
TIMER
SPECIAL
SCREEN
Prev.
Menu
Set ID
Set ID
PICTURE
SOUND
TIMER
SPECIAL
SCREEN
Prev.
Menu
Language
Child lock
ISM Method
Set ID
Tile mode
Low power
Demo
Fan
- Use this function to specify a monitor ID number.
- Refer to ‘Real Data Mapping 1’. See page 35.
1. Press the MENU button and then use the
D
D
/
E
E
button to select the
SPECIAL
menu.
2. Press the
G
G
button and then use
D
D
/
E
E
button to select
Set ID
.
3. Press the
G
G
button and then use
F
/
G
button to adjust
Set ID
to choose the desired monitor ID number.
• The adjustment range of
Set ID
is 1 ~ 99.
Language
Child lock
ISM Method
Set ID
G
G
Tile mode
Low power
Demo
Fan
1
Содержание 50PM4M
Страница 46: ......