Plasma Spring 2009
50PG20
87
CONTROL PWB SECTION
CONTROL PWB SECTION
• DC Voltage and Waveform Test Points
• Resistance Test Points
Signals
Signals
Y SUS Supplied
5V VCC
Developed on the
1.8V
Control board
(2) 3.3V
This Section of the Presentation will cover troubleshooting the Control Board Assembly. Upon completion
of this section the Technician will have a better understanding of the circuit and be able to locate voltage
and resistance test points needed for troubleshooting.
Main Board Supplied
LVDS Signal
Operating Voltages
Operating Voltages
Y
Y
SUS
SUS
Supplied
Supplied
15V supplied to Control board from the Y-SUS board.
But routed through Control board to Z-SUS.
15V not used by the Control board.
Содержание 50PG20 Series
Страница 15: ...Plasma Spring 2009 50PG20 15 50PG20 Remote Control 50PG20 Remote Control TOP PORTION BOTTOM PORTION ...
Страница 16: ...Plasma Spring 2009 50PG20 16 Rear and Side Input Jacks Rear and Side Input Jacks ...
Страница 18: ...Plasma Spring 2009 50PG20 18 50PG20 Dimensions 50PG20 Dimensions ...
Страница 26: ...Plasma Spring 2009 50PG20 26 Signal and Voltage Distribution Signal and Voltage Distribution ...
Страница 43: ...Plasma Spring 2009 50PG20 43 STATIC TEST UNDER LOAD LIGHT BULB TEST STATIC TEST UNDER LOAD LIGHT BULB TEST ...
Страница 102: ...Plasma Spring 2009 50PG20 102 TCP IC s shown are part of the Ribbon Cable X Drive Left PWB X Drive Left PWB ABUS ABUS ...
Страница 103: ...Plasma Spring 2009 50PG20 103 X Drive Center PWB X Drive Center PWB ABUS ABUS ...
Страница 104: ...Plasma Spring 2009 50PG20 104 X Drive Right PWB X Drive Right PWB ABUS ABUS TCP IC s shown are part of the Ribbon Cable ...
Страница 127: ...129 Plasma Spring 2009 50PG20 This concludes the Presentation Thank You End of Presentation End of Presentation ...