5.2. Adjustment White balance
● W/B Equipment condition
CA210 : CH 9, Test signal : Inner pattern (80IRE) – LAMP
Module
CH14 , Test signal : Inner pattern (80IRE) – LED
Module
CH18 , Test signal : Inner pattern (80IRE) – ALEF
Module
● Above 5 minutes H/run in the inner pattern. (“power on” key of
adjust remote control)
※
The spec of color temperature and coordinate.
All
Cool (C50)
13,000k
K
X=0.271
(±0.002)
Y=0.270
(±0.002)
<Test signal>
- Inner pattern
for W/B adjust
- External white
pattern (80IRE,
204gray)
Medium (0)
9,300k
K
X=0.286
(±0.002)
Y=0.289
(±0.002)
Warm (W50)
6,500k
K
X=0.313
(±0.002)
Y=0.329
(±0.002)
※
Normal line(LGD Module (LB5xxx, LB6xxx, LB7xxx, LB8xxx))
- Except Winter Season ( Jan. , Feb. ) and Global table
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
271
270
286
289
313
329
1
0-2
282
289
297
308
324
348
2
3-5
281
287
296
306
323
346
3
6-9
279
284
294
303
321
343
4
10-19
277
280
292
299
319
339
5
20-35
275
277
290
296
317
336
6
36-49
274
274
289
293
316
333
7
50-79
273
272
288
291
315
331
8
80-119
272
271
287
290
314
330
9
Over 120
271
270
286
289
313
329
※
AUO, INX, Sharp, CSOT, BOE Model (in case, Cool spec =
13000K)
cool
med
warm
x
y
x
y
x
y
spec
271
270
286
289
313
329
target
278
280
293
299
320
339
※
Connecting picture of the measuring instrument (On Automatic
control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER-ON -> Enter
the mode of White-Balance, the pattern will come out
● Auto-control interface and directions
(1) Adjust in the place where the influx of light like floodlight
around is blocked. (Illumination is less than 10ux).
(2) Adhere closely the Color Analyzer ( CA210 ) to the module
less than 10cm distance, keep it with the surface of the
Module and Color Analyzer’s Prove vertically.(80~100°).
(3) Aging time
- After aging start, keep the power on (no suspension of power
supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others, check the
back light on.
● Auto adjustment Map(RS-232C)
RS-232C COMMAND
[ CMD ID DATA ]
Wb 00 00 White Balance Start
Wb 00 ff White Balance End
RS-232C COMMAND
[CMD ID DATA]
MIN
CENTER
(DEFAULT)
MAX
Cool
Mid
Warm
00
Cool
Mid
Warm
R Gain
Jg
ja
jd
00
172
192
192
192
G Gain
Jh
jb
je
00
172
192
192
192
B Gain
Ji
jc
jf
192
192
172
192
R Gain
64
64
64
128
G Gain
64
64
64
128
B Gain
64
64
64
128
Содержание 50LB6500