Establish : 12/09/15
LC36B Adjust specification
LG(55)C2-0661-00
18/25
Reform : 12/09/15
LG electronics
MODEL NAME
HEX
EDID Table
DDC Function
HD/FHD Model
0001
01 00
Analog/Digital
ⓑ
Serial No : Controlled on production line.
ⓒ
Month, Year : Week : ‘01’
è
‘01’ Year : ‘2012’
è
‘16’ fix
ⓓ
Model Name(Hex) : Refer to the ASCII Code Table.
Cf) model name in EDID data is below.
MODEL NAME
MODEL NAME(HEX)
LG TV
00 00 00 FC 00 4C 47 20 54 56 0A 20 20 20 20 20 20 20 (LG TV)
ⓔ
Checksum: Changeable by total EDID data.
5.5 Outgoing condition Configuration
■ When pressing IN-STOP key by SVC remocon, Red LED are blinked alternatively. And then automatically turn off.
(Must not AC power OFF during blinking)
5.6 GND and HI-POT Test
5.6.1. GND & HI-POT auto-check preparation
(1) Check the POWER CABLE and SIGNAL CABE insertion condition
5.6.2. GND & HI-POT auto-check
(1) Pallet moves in the station. (POWER CORD / AV CORD is tightly inserted)
(2) Connect the AV JACK Tester.
(3) Controller (GWS103-4) on.
(4) GND Test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, execute next process (Hi-pot test). (Remove A/V CORD from A/V JACK BOX)
(5) HI-POT test (Auto)
- If Test is failed, Buzzer operates.
- If Test is passed, GOOD Lamp on and move to next process automatically.
EDID C/S data
FHD–8BIT
HDMI
check
sum
(Hex)
Block 0 42
Block 1
25 (HDMI1)
15 (HDMI2)
EDID C/S data
HD
HDMI
check
sum
(Hex)
Block 0 A3
Block 1
5B (HDMI1)
4B (HDMI2)