D. Function error
Remote control & Local switch checking
Y
N
1. Remote control(R/C) operating error
Check R/C itself
Operation
Y
Replace R/C
If R/C operate,
Explain the customer
cause is interference
from light in room.
Check R/C Operating
When turn off light
in room
Check & Replace
Baterry of R/C
Check & Repair
Cable connection
Connector solder
Check B+ 3.5V
On Main B/D
☞
A17
N
N
Check 3.5v on Power B/D
Replace Power B/D or
Replace Main B/D
(Power B/D don’t have problem)
Check IR
Output signal
N
Y
Repair/Replace
IR B/D
N
☞
A17
Replace
Main B/D
Y
☞
A17
Standard Repair Process
Established
date
Revised date
11/14
Error
symptom
End
Normal
Operating
Normal
Voltage
Normal
Signal
Normal
Operating
Normal
Operating
End
Y
Copyright © 2017 LG Electronics Inc. All rights reserved.
Only for training and service purposes.