Standard Repair Process Detail Technical Manual
Remote control operation checking method
D. Function error
A22
Established
date
Revised
date
Error
symptom
Content
A22
②
③
Checking order
1.Check BT/Wifi cable condition between BT/Wifi assy & Main board.
2.Check the 3.5V on the terminal 1
Checking order to check motion remote/wifi
① Wifi & BT Front
Wifi & BT Rear
<ALL MODELS>
1
+3.5V
2
WIFI_DM
3
WIFI_DP
4
GND
5
WOL_ON
6
3.5V
7
COMBO_RESET
8
GND
9
COMBO_WAKEUP_DEVICE
10 COMBO_WAKEUP_HOST
11 GND
12 GND
13 NC
14 NC
15 NC
16 EYE_SDA
17 EYE_SCL
18 GND
19 IR
20 LED
21 GND
22 3.5V
23 KEY2
24 KEY1
25 GND
Copyright © 2017 LG Electronics. Inc. All rights reserved.