- 19 -
4. No Raster
(1) Symptom
¯
Does’t minute discharge at module.
¯
It maintains the condition where the front LED is green.
(2) Check follow
Is normal the Power
Board?
Replace Power
Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is normal the each
connector?
Replace
connector.
Replace
Y-Board.
After connecting well each connector,
the normality it operates?
Yes
No
No
Is normal the
Ctrl Board?
Replace
X-Board.
Is normal the output voltage after
remove P1, 2, 4, 9, 10 connector of
Ctrl-B/D?
Yes
No
Yes
Is normal the
Y- Board?
Is normal the output
voltage after remove
P5, P6 connector of
Y-B/D?
Is normal the Fuse(FS2) on Y-B/D?
(In case of open is replace)
Yes
No
Yes
Yes
Replace
Z-Board.
Is normal the
Z- Board?
Is normal the output
voltage after remove
P1 connector of
Z-B/D?
Is normal the Fuse(FS1, FS2) on Z-
B/D? (In case of open is replace)
Yes
No
Yes
Is normal the
X- Board?
Is normal the output voltage after
remove P1, 2, 3, 4, 5 connector of
X-B/D?
After remove P1, P2, P3 output voltage
normality: Replace Right X-B/D
After remove P4, P5 output voltage
normality: Replace Left X-B/D
Yes
No
Yes
Is normal the
VSC Board?
Is normal the output voltage after
remove P1001, P1100?
After crisis COF of each board, check the normality operates.
If in case normality operates, correspondence COF Fail is
replace the module.
After remove P1001, P1100 normal
operation: Replace VSC Board
Yes
No
Is normal the
COF of X, Y, Z?
No
Yes
Yes
Содержание 42PX2RVA
Страница 15: ... 15 1 2 Sony Power Board Structure 1 2 3 T502 Vs Trans T702 Va Trans T101 St by Trans T103 Low Voltage Trans ...
Страница 16: ... 16 1 3 Sanken Power Board Structure 1 2 3 T221 Vs Trans T271 Va Trans T121 St by Trans T201 Low Voltage Trans ...
Страница 23: ... 23 BLOCK DIAGRAM ...
Страница 31: ......
Страница 32: ......
Страница 33: ......
Страница 35: ...May 2005 Printed in Korea P NO 3828VD0209U ...