- 11 -
LGE Internal Use Only
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5.1.5. Adjustment method
5.1.5.1. Auto WB calibration
(1) Set TV in ADJ mode using P-ONLY key (or POWER ON
key)
(2) Place optical probe on the center of the display
- It need to check probe condition of zero calibration before
adjustment.
(3) Connect RS-232C Cable
(4) Select mode in ADJ Program and begin a adjustment.
(5) When WB adjustment is completed with OK message,
check adjustment status of pre-set mode (Cool, Medium,
Warm)
(6) Remove probe and RS-232C cable.
*
W/B Adj. must begin as start command “wb 00 00” , and
finish as end command “wb 00 ff”, and Adj. offset if need.
5.1.5.2. Manual adj. method
(1) Set TV in Adj. mode using POWER ON
(2) Zero Calibrate the probe of Color Analyzer, then place it on
the center of LCD module within 10cm of the surface.
(3) Press ADJ key -> EZ adjust using adj. R/C -> 6. White-
Balance then press the cursor to the right (KEY►).
(When KEY(►) is pressed 204 Gray(80IRE) internal
pattern will be displayed)
(4) One of R Gain / G Gain / B Gain should be fixed at 192,
and the rest will be lowered to meet the desired value.
(5) Adj. is performed in COOL, MEDIUM, WARM 3 modes of
color temperature.
* CASE
First adjust the coordinate far away from the target value(x, y).
1. x, y > target
1) Decrease the R, G.
2. x, y < target
1) First decrease the B gain,
2) Decrease the one of the others.
3. x > target , y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
4. x < target, y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
► How to adjust
1.Fix G gain at least 172
Adjust R, B Gain ( In Case of Mostly Blue Gain Saturation)
2. When R or B Gain > 255, Release Fixed G Gain and
Readjust
* CASE Medium / Warm
First adjust the coordinate far away from the target value(x, y).
1. x, y > target
1) Decrease the R, G.
2. x, y < target
1) First decrease the B gain,
2) Decrease the one of the others.
3. x > target, y < target
1) First decrease B, so make y a little more than the target.
2) Adjust x value by decreasing the R
4. x < target, y > target
1) First decrease B, so make x a little more than the target.
2) Adjust x value by decreasing the G
5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
**(normal line) Model : For LGD (LF54xx)
▪ Standard color coordinate and temperature using CA-210(CH
14) – by aging time
**(aging chamber) Model : For LGD (LF54xx)
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
** For INX,AUO,SHARP,CSOT Module.( In the case of , the
color temperature spec of cool mode is 13000K)
L16 Aging time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-2
281
285
296
304
323
344
2
3-5
280
284
295
303
322
343
3
6-9
279
282
294
301
321
341
4
10-19
277
279
292
288
319
338
5
20-35
275
275
290
294
317
334
6
36-49
273
273
288
292
315
332
7
50-79
272
272
287
291
314
331
8
80-119
271
270
286
289
313
329
9
Over 120
271
270
286
289
313
329
L16 Aging time
(Min)
Cool
Medium
Warm
x
y
x
y
x
y
271
270
286
289
313
329
1
0-2
280
285
295
304
319
340
2
3-5
276
280
291
299
315
335
3
6-9
272
275
287
294
311
330
4
10-19
269
272
284
291
308
327
5
20-35
267
268
282
287
306
323
6
36-49
266
265
281
284
305
320
7
50-79
265
263
280
282
304
318
8
80-119
264
261
279
280
303
316
9
Over 120
264
260
279
279
303
315
Cool
med
warm
x
y
x
y
x
y
spec
271
270
286
289
313
329
target
276
277
291
296
318
336
Содержание 40LH5300
Страница 21: ......