background image

Safety Precautions  

Owner's Manual  3

ENGLISH

Safety Precautions

To prevent injury to the user or other people and property damage, the following instructions
must be followed.

Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classified by the following indications.

Meanings of symbols used in this manual are as shown below.

WARNING

CAUTION

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage.

Be sure not to do.

Be sure to follow the instruction.

WARNING

Installation

Do not use a defective or
underrated circuit breaker.
Use this appliance on a
dedicated circuit.

• There is risk of fire or electric

shock.

For electrical work, contact
the dealer, seller, a qualified
electrician, or an Authorized
Service Center.

• Do not disassemble or repair the

product. There is risk of fire or
electric shock.

Always ground the product.

• There is risk of fire or electric

shock.

Install the panel and the
cover of control box
securely.

• There is risk of fire or electric

shock.

Always install a dedicated
circuit and breaker.

• Improper wiring or installation

may cause fire or electric shock

Use the correctly rated
breaker or fuse.

• There is risk of fire or electric

shock.

Содержание 3828A22005P

Страница 1: ...air conditioner Please retain this owner s manual for future reference after reading it thoroughly Prior to installation this air conditioning unit must be submitted for approval by the utility service which provides electricity EN 61000 2 EN 61000 3 Norm website http www lgservice com LG Cassette Type Air Conditioner FRANÇAIS ESPAÑOL ...

Страница 2: ...o common problems in the chart of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact the authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young chi...

Страница 3: ...e sure to follow the instruction WARNING Installation Do not use a defective or underrated circuit breaker Use this appliance on a dedicated circuit There is risk of fire or electric shock For electrical work contact the dealer seller a qualified electrician or an Authorized Service Center Do not disassemble or repair the product There is risk of fire or electric shock Always ground the product Th...

Страница 4: ...to the product Be sure the installation area does not deteriorate with age If the base collapses the air conditioner could fall with it causing property damage product failure and personal injury Do not plug or unplug the power supply plug during operation There is risk of fire or electric shock Do not touch operate the product with wet hands There is risk of fire or electrical shock Do not place ...

Страница 5: ...risk of electric shock or fire Stop operation and close the window in storm or hurricane If possible remove the product from the window before the hurricane arrives There is risk of property damage failure of product or electric shock Do not open the inlet grill of the product during operation Do not touch the electrostatic filter if the unit is so equipped There is risk of physical injury electri...

Страница 6: ...e product where it will be exposed to sea wind salt spray directly It may cause corrosion on the product Corrosion particularly on the condenser and evaporator fins could cause product malfunction or inefficient operation 90 When the product is not be used for a long time disconnect the power supply plug or turn off the breaker There is risk of product damage or failure or unintended operation Tak...

Страница 7: ...t malfunction or damage Do not insert hands or other objects through the air inlet or outlet while the product is operated There are sharp and moving parts that could cause personal injury Do not drink the water drained from the product It is not sanitary and could cause serious health issues Use a firm stool or ladder when cleaning or maintaining the product Be careful and avoid personal injury R...

Страница 8: ...e time of first operating unit Timer Lights up during Timer operation Forced Operation procedures when the remote control Operation can t be used Outdoor Unit Lights up during outdoor unit operation Operation Signal Receiver Receives the signals from the remote control Signal receiving sound two short beeps or one long beep Anti bacteria Anti bacteria Remote Controller Air Outlet Air Intake Signal...

Страница 9: ...er when the desired time is obtained Week Button Used to set a day of the week Program Button Used to set the weekly timer Holiday Button Used to set a holiday of the week Time Set Button Used to set the time of the day and change the time in the weekly timer Function Set and Clear Button Used to set and clear the weekly timer Swirl Button Used to select swirl mode Reset Button Used to set the cur...

Страница 10: ...sed to select the operation mode 3 ROOM TEMPERATURE SETTING BUTTONS Used to select the room temperature 4 INDOOR FAN SPEED SELECTOR Used to select fan speed in four steps low medium high and CHAOS 5 JET COOL Used to start or stop the speed cooling speed cooling operates super high fan speed in cooling mode 6 AUTO SWING BUTTON Used to stop or start louver movement and set the desired up down airflo...

Страница 11: ...TO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP Hour Min Week RESET Operating Instructions Set the Current Time and day of the Week Unless you press any button about 5 sometimes 10 seconds while setting function the setting mode returns to initial mode 1Press the button Each t...

Страница 12: ...4 OPERATION FAN SPEED SUB FUNCTION SET TEMP 01 03 05 07 09 11 13 15 17 19 21 23 Time Operating Instructions Weekly Programming 1Press the Program button The remote controller is displayed like a picture Then and 01 is blinked 2 Press the button Press button repeatedly until desired mode appears For example if you want Thu press button 4 times 3Select the time you want Press or button then blinking...

Страница 13: ... Time AUTO SWING Time HI ZONE Operation unit Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Timer On Set no Off 1 2 3 4 OPERATION FAN SPEED SUB FUNCTION SET TEMP 01 03 05 07 09 11 13 15 17 19 21 23 Time AUTO SWING Program set Program set Time HI ZONE Operation unit Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Timer On Set no Off 1 2 3 4 OPERA...

Страница 14: ...SUB FUNCTION SET TEMP Room Temp HI MED LO Heater Defrost Filter Preheat Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 2ndF AUTO SWING 3 1 4 2 Operating Instructions Operation Mode Operation Procedure Cooling Mode Soft Dry Mode Auto Mode 1st 2nd 3rd 4th On Off Button Operation Mode Selection Button Room Temperature Setting Button Indoor Fan Speed Selection Button ...

Страница 15: ... Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP HI MED LO Defrost Filter Out door AUTO HI Heater Preheat Time Room Temp Operation unit No Func Program set Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 2ndF ZONE 1 2 3 4 Humidify SLo OPERATION FAN SPEED SUB FUNCTION SET TEMP AUTO SWING JET JET MED...

Страница 16: ...tion Auto Operation ZONE Operation unit Program set Room Temp MED LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP HI HI ZONE Operation unit Program set Room Temp MED AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05...

Страница 17: ...ure To lower the Temperature Cold Cool Proper Warm Hot Auto Operation Mode 1Press the On Off Button 2To select Auto Operation press the Operation Mode Selection button Each time the button is pressed the operation mode is shifted in the direction of the arrow During Auto Operation You cannot switch the indoor fan speed It has already been set by the Fuzzy rule If the system is not operating as des...

Страница 18: ...ONE Operation unit Program set Room Temp MED AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 AUTO SWING OPERATION FAN SPEED SUB FUNCTION SET TEMP LO HI ZONE Operation unit Program set Room Temp LO AUTO JET Heater Defrost Filter Preheat Humidify Out door Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 ...

Страница 19: ...E 1 2 3 4 Humidify JET SLo UNCTION Heater Defrost Filter Preheat Outdoor 9 11 13 15 17 19 21 23 Operating Instructions Owner s Manual 19 ENGLISH Comfort Operation with Swirl It is the function for comfort cooling heating operation The diagonal two louvers are opened the more larger than the other louvers After one minute it is opposite 1Press the On Off Button The unit will respond with a beep 2Pr...

Страница 20: ... 21 23 1 2 3 4 JET AUTO SWING OPERATION FAN SPEED SUBFUNCTION SETTEMP AUTO LO HI ZONE Operation unit Program set RoomTemp MED Heater Defrost Filter Preheat Humidify Outdoor Time Timer On Set no Time Off 01 03 05 07 09 11 13 15 17 19 21 23 1 2 3 4 JET AUTO SWING OPERATION FAN SPEED SUBFUNCTION SETTEMP AUTO LO HI ZONE Operation unit Program set RoomTemp MED Heater Defrost Filter Preheat Humidify Out...

Страница 21: ...peration procedure To set the Child Lock Function Press the Timer button and Minute Set button for three seconds Then the operation mode shift to child lock mode and it is displayed CL in the operation display When you press any button in this time the remote controller is not converted to any selected mode and the CL is displayed in the remote controller for about three seconds But the Room Tempe...

Страница 22: ...uto Restarting Operation is the function to operate procedures automatically to the previous operating conditions Filter sign lamp LED is ON If LED indicating filter sign lamp is ON clean the filter After cleaning the filter press the Timer button and button of wired remote controller at the same time for 3 sec Then filter sign LED is OFF Heat pump Model Cooling Model Room Temp set Temp 2 C Room T...

Страница 23: ...sing a vacuum cleaner or washing with water If dirt is conspicuous wash with a neutral detergent in lukewarm water If hot water 50 C or more is used it may be deformed After washing with water dry well in the shade Do not expose the air filter to direct sunlight or heat from a fire when drying it Install the air filter Air Filters The air filters behind the front grille should be checked and clean...

Страница 24: ...or 20 30 minutes Dry the PLASMA filter in the shade for a day Especially the humidity must be removed perfectly on this parts Note the cuts of electric discharge lines Re install the PLASMA filter to the original position 1 2 3 4 5 Replacement Recomended use period About 2 years Open front panel and remove air filter Remove air purifying filter Insert new air purifying filter 1 2 3 Reinsert air fi...

Страница 25: ...hat the ground wire is connected correctly It may be connect to the indoor unit side Do not overcool the room This is not good for the health and wastes electricity Keep blinds or curtains closed Do not let direct sunshine enter the room when the air conditioner is in operation Keep the room temperature uniform Adjust the vertical and horizontal airflow direction to ensure a uniform temperature in...

Страница 26: ... when the airflow from the air conditioner cools the warm room air This is the protector of the mechanism Wait about three minutes and operation will begin Is the air filter dirty See air filter cleaning instructions The room may have been very hot when the room air conditioner was first turned on Allow time for it to cool down Has the setting temperature been set incorrectly Are the indoor unit s...

Страница 27: ...P No 3828A22005P Printed in Korea After reading this manual keep it in a place easily accessible to the user for future reference ...