LG Packaged Terminal Air Conditioner Limited Warranty - USA

Should your LG Packaged Terminal Air Conditioner prove to be defective in materials or workmanship under normal use during 
the warranty period listed below, LG Electronics will replace the defective part(s). Replacement part(s) will meet intended fit and 
function of the original part(s). Replacement parts are warranted for the unexpired portion of the original warranty period. This 
warranty is good only to the original purchaser of the product and effective only when used in the United States.

No other warranty is applicable to this product. THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, 
EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, IT IS LIMITED 
IN DURATION TO THE EXPRESS WARRANTY PERIOD ABOVE. NEITHER THE MANUFACTURER NOR ITS U.S. 
DISTRIBUTOR SHALL BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE 
DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS, OR ANY OTHER 
DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. Some states and/or territories do not allow the 
exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts, so 
the above exclusion or limitation may not apply to you. This warranty gives you, the original purchaser, specific legal 
rights and you may also have other rights that vary from state to state or territory to territory.

THIS LIMITED WARRANTY DOES NOT APPLY TO:

1.

Service trips to your home for delivery or pickup, install, instruct or replace house fuses, or connect
house wiring or plumbing, or correction of unauthorized repairs.

2.

Failure of product to perform during power failures and interruptions or inadequate electrical service.

3.

Damage caused by transportation or handling.

4.

Damage to the product caused by accident, vermin, lightning, winds, fire, floods, or acts of God.

5.

Damages caused by leaky or broken water pipes, frozen water pipes, restricted drain lines, or 
inadequate or interrupted water supply.

6.

Damages cause by inadequate supply of air.

7.

Damages resulting from running the product in a corrosive atmosphere.

8.

Repairs when your LG product is used in other than normal, single-family household use or contrary to 
the instructions outlined in the product owner's manual.

9.

Damage resulting from accident, misuse, abuse, or improper installation, repair, or maintenance. 
Improper repair includes use of parts not approved or specified by LG.

10. Normal maintenance as described in the installation instructions and use and care manual, such as 

replacing filters, cleaning of coils, etc.

11. Use of accessories or components that are not compatible with this product.
12. Products with altered or removed serial numbers.
13. Changes in the appearance of the product that do not affect product performance.
14. Increases in utility costs and additional utility expenses.
The cost of repair or replacement under these excluded circumstances shall be borne by the consumer.

WARRANTY PERIOD: 

For The Period Of:

One Year
From the date of the 
original purchase

Any part of LGE Packaged Terminal which fails due to a defect in materials or workmanship. During this 
full one-year warranty, LGE will also provide, free of charge, all labor and on-site service to replace 
the defective part. 

Five Years
From the date of the 
original purchase

Any part of the sealed refrigerating system (the compressor, condenser, evaporator and all 
connecting tubing) which fails due to a defect in materials or workmanship. During this full five-year 
sealed refrigerating system warranty
, LGE will also provide, free of charge, all labor and on-site 
service to replace the defective part.

Five Years
From the date of the 
original purchase

For the second through the fifth year from the date of original purchase, LGE will replace certain 
parts
 that fail due to a defect in materials or workmanship. Parts covered are fan motors, switches, 
thermostats, heater, heater protectors, compressor overload, solenoids, circuit boards, auxiliary controls, 
thermistors, frost controls, ICR pump, capacitors, varistors and indoor blower bearing, During this limited 
four-year parts warranty
, you will be responsible for any labor or on-site service costs.

LGE Will Replace:

Содержание 3828A20255J

Страница 1: ...safety precautions carefully and thoroughly before installing and operating your air conditioner IMPORTANT Please read through this manual It contains valuable information about your air conditioner This manual may help save time and money by explaining proper air conditioner maintenance and preventing improper use ENGLISH ESPAÑOL ...

Страница 2: ... of troubleshooting tips If you review our chart of Troubleshooting Tips first you may not need to call for service at all PRECAUTION Contact an authorized service technician for repair or maintenance of this unit Contact the installer for installation of this unit The air conditioner is not intended for use by young children or invalids without supervision Young children should be supervised to e...

Страница 3: ...ity of injury or damage to properties only WARNING Installation Don t do this Be sure to follow the instruction Don t use a power cord a plug or a loose socket which is damaged It may cause a fire or electrical shock Always plug into a grounded outlet It may cause a fire or electrical shock Do not modify or extend the power cord length It will cause electric shock or fire due to heat generation Do...

Страница 4: ...er switch when not using it for a long time Prevent accidental startup and the possibility of injury Unplug the unit if strange sounds odors or smoke come from it It could represent a fire hazed Do not open the suction inlet grill of the product during operation Otherwise it may electrical shock and failure If water enters the product turn off the the power switch of the main body of appliance Con...

Страница 5: ...k Hold the plug by the end when taking it out It may cause electric shock and damage When gas leaks open the window for ventilation before operating the unit Otherwise it may cause an explosion and a fire Never touch the metal parts of the unit when removing the filter They are sharp and may cause injury Install the product so that the noise or exhaust from the outdoor unit may not cause any damag...

Страница 6: ...es brush your teeth and see doctor Do not use the remote if the batteries have leaked The chemicals in batteries could cause burns or other health hazards Do not put a pet or house plant where it will be exposed to direct air flow It is not good to sit in the draft Do not block the inlet or outlet of air flow It may cause product failure Use a soft cloth to clean Do not use wax thinner or a strong...

Страница 7: ...n deficiency ventilate the room when used together with stoves or other heating devices 3 Do not use this air conditioner for non specified special purposes e g preserving precision devices food pets plants and art objects Such usage could damage the items 1 Do not touch the metal parts of the unit when removing the filter Injuries can occur when handling sharp metal edges 2 Do not use water to cl...

Страница 8: ...Grille Should be applied for better performance in PTAC and PTHP Units For Installation purpose and better appearance Aluminium or Architectural grille can be applied in PTAC and PTHP Units Introduction Symbols Used in this Manual Features I N D O O R REAR GRILLE Aluminum Rear Grille EXPANDED METAL GRILLE For Superior Performance SLEEVE ASSEMBLY Including Aluminum Rear Grille THE SLEEVE AND THE RE...

Страница 9: ... this plug can damaged This device contains chemicals including lead known to the State of California to cause cancer birth defects or other reproductive harm Wash hands after handling Do not remove modify or immerse this plug If this device trips the cause should be corrected before further use The conductors inside this cord are surrounded by shields which monitor leakage current These shields a...

Страница 10: ...ge slot in the receptacle to assure a proper polarity connection Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance unless the cover screw is metal and not insulated and the wall receptacle is grounded through the house wiring The customer should have the circuit checked by a qualified electrician to make sure the receptacle is properly grounded ...

Страница 11: ...n and have the rear grille that securely attaches to the sleeve or the flange of the sleeve to secure the new air conditioner To avoid vibration and noise make sure the unit is installed securely and firmly When installing the sleeve make certain there is nothing within 20 of the back that would interfere with heat radiation and exhaust air flow To maintain the best performance of the LG PTAC an i...

Страница 12: ...oor 2 Remove the front gille by pulling it out at the bottom to release it then lift it up along the unit top front 3 Slide the unit into the wall sleeve and secure with 6 screws through the unit flange holes 4 Reinstall the front grille by hooking the top over the unit top then pushing it in at the bottom ...

Страница 13: ...d fan operation HIGH HEAT Heating with the high speed fan operation VENTILATION The ventilation lever is located to the lower left side of the unit The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions When fresh air is necessary in the room set the ventilation lever to the OPEN position The damper is opened and outdoor air is drawn into the room This...

Страница 14: ...eration TIMER SHUT OFF TIME You will usually use shut off time while you sleep If unit is running use Timer to set number of hours until shut off For your sleeping comfort once Time is set the Temperature setting will raise 2 F after 30 minutes and once again after another 30 minutes Push Timer to cycle through the settings from 1 Hour 2 Hours 12 Hours maximum TEMPERATURE SETTING Use this button t...

Страница 15: ...engineer should go fully prepared with the prescribed tools to be used regarding that problem It also keeps the customer aware about the unit Here are some of the problems defined below for which the LED indicates by flashing number of times the error has been reconrded against it The errors are the mentioned in the Table 13 which is as follows ON Normal OFF No power failed board Fault Codes CH 01...

Страница 16: ...FF 5 LOCAL 1 OFF 2 OFF 3 OFF 4 OFF 5 ON ON REMOTE OFF ON ON ON Remote Local Energy Saver Temperature Limit 1 Temperature Limit 2 Temperature Limit 3 PTAC PTHP UNIT TYPE LOCAL LOCAL 1 OFF OFF 2 OFF OFF 3 OFF OFF 4 OFF OFF 5 LOCAL 1 OFF 2 OFF 3 OFF 4 OFF 5 LOCAL LOCAL 1 OFF OFF 2 OFF OFF 3 OFF OFF 4 OFF OFF 5 LOCAL 1 OFF 2 OFF 3 OFF 4 OFF 5 OFF 6 OFF 7 LOCAL LOCAL 1 OFF OFF 2 OFF OFF 3 OFF OFF 4 OFF...

Страница 17: ...imit 2 Limit 3 Lowest Temp Highest Temp Lowest Temp Highest Temp Cooling Operation Heating Operation REMOVING THE FRONT GRILLE Additional controls are available after removing the front grille and option cover of control box To remove the front grille pull out the bottom of front grille and then lift up To replace the front grille place the tabs over the top of the unit and push the bottom of fron...

Страница 18: ...ng without working compressor and heater When the front desk switch is OFF the unit can operate according to the setting of controls REMOTE WALL THERMOSTAT When the wires are connected the unit will be controlled by a remote wall thermostat The thermostat connections supply the 24 Volt AC When you install the digital electronic thermostat you must set it to 24 Volt AC See the installation Instruct...

Страница 19: ...te Wall Thermostat REMOTE LOCAL CONTROL When remote local switch 1 is on it allow the unit to operate by the control of Remote Wall Thermostat The unit control by knobs are not available ENERGY SAVER The energy saver switch 2 is on This switch is set at continuous fan to provide continuous fan operation in cool or heat modes When the switch is off the continuous fan allows continuous circulation o...

Страница 20: ... the top of the unit through reversible 2 position discharge grille louvers The unit is shipped from the factory with the discharge grille louvers at an angle of 40 off vertical In an alternate position the louvers will be at an angle of 15 off vertical To adjust the air direction remove the front grille Remove the 4 screws that fasten the discharge grille to the front grille Flip the discharge gr...

Страница 21: ... completely Replace the filter Before cleaning the vent filter disconnect power to the unit by unplugging the power cord at the wall outlet or subbase or disconnect power at the fuse box or circuit breaker If unit is operated with vent door closed the vent filter does not need to be cleaned 1 Remove the cabinet front as described in Front Removal 2 Remove the six screws securing the chassis to the...

Страница 22: ...same manner as above The base pan may overflow due to high humidity To drain the excess water remove the drain cap from the back of the unit The compressor and fan motor are hermetically sealed permanently lubricated and require no additional oiling The cabinet front and discharge air grille can be cleaned with a mild soap or detergent Under no circumstances should hydrocarbon based cleaners e g a...

Страница 23: ...load Check voltage at outlet Correct if none Check voltage to rotary switch If none check power supply cord Replace cord if circuit is open Check switch continuity Refer to wiring diagram for terminal identification Replace switch if defective Connect wire Refer to wiring diagram for terminal identification Repair or replace loose terminal Test capacitor Replace if not within 10 of manufacturer s ...

Страница 24: ...erminal If wires are off refer to wiring diagram for identification and replace Check wire locations If not per wiring diagram correct Check for continuity refer to the wiring diagram for terminal identification Replace the switch if circuit is open Check the position of knob If not at the coldest setting advance the knob to this setting and restart unit Check continuity of the thermostat Replace ...

Страница 25: ...uired Remove the cabinet inspect the interior surface of the condenser if restricted clean carefully with a vacuum cleaner do not damage fins or brush Clean the interior base before reassembling If condenser fins are closed over a large area on the coil surface head pressures will increase causing the compressor to cycle Straighten the fins or replace the coil Test capacitor Check the terminals If...

Страница 26: ...50 Aparato de aire acondicionado Nota ...

Страница 27: ...pipes frozen water pipes restricted drain lines or inadequate or interrupted water supply 6 Damages cause by inadequate supply of air 7 Damages resulting from running the product in a corrosive atmosphere 8 Repairs when your LG product is used in other than normal single family household use or contrary to the instructions outlined in the product owner s manual 9 Damage resulting from accident mis...