- 16 -
Copyright © 2007 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
2. Protect mode
(1) Symptom
1) After once shining, it does not discharge minutely from module.
2) The relay falls.(The sound is audible “Click”.)
3) It is converted with the color where the front LED is red from green.
(2) Check follow
Is normal the Power
Board?
Replace Power Board.
Is output the normality Low/High
voltage except Stand-by 5V?
Yes
No
No
Is normal the each
connector?
Replace connector.
After connecting well each connector,
the normality it operates?
Yes
No
No
Is normal the VSC
Board?
After remove P900, P901
normal operation:
Replace VSC Board
Is normal the output voltage after
remove P900, P901 of VSC Board?
No
Yes