- 16 -
LGE Internal Use Only
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
Does minute discharge
At Module?
Is the LVDS cable
connect well from Ctrl
Board to VSC Borad?
Replace FLI106X0H
IC(IC100)
Is the VaVs normal?
Check the PDP Module
Yes
No
YES
Yes
Reconnect the LVDS
cable in P501
No
Is normal the VSC
Board?
Operates the FLI106X0H(IC100)?
1. Check the Monitor OUT by SCART2 : Connect the another TV SET
2. Check the LVDS clock(R537,R538) on the VSC Borad by Oscilloscope?
Replace the
VSC B/D.
No
NO
Replace the
Power board
Is output the normality
Low/High voltage except
stand-by 5V?
NO
4. No Raster
(1) Symptom
1) No OSD and image occur at screen.
2) It maintains the condition where the front LED is green.
(2) Check the followings
Yes
No
Содержание 32PG6000
Страница 34: ...June 2008 Printed in Korea P NO MFL41181008 ...