- 7 -
ⓐ
Product ID
ⓑ
Serial No
=> Controlled on production line
ⓒ
Month, Year
=> Controlled on production line:
ex) Monthly: ‘11’ -> ‘0B’
Year: ‘2006’ -> ‘10’
ⓓ
Model Name/Monitor Name
ⓔ
Checksum(7EH)
=> Changeable by total EDID data
4-2. Required Test Equipment
(1) Adjusting PC with S/W for writing EDID Data.(S/W : EDID
TESTER Ver.2.5)
(2) A Jig for EDID Download
(3) Cable : Serial(9Pin or USB) to D-sub 15Pin cable, D-sub
15Pin cable, DVI to HDMI cable.
4-3. Preparation for Adjustment
(1) As above (Fig. 1), Connect the Set, EDID Download Jig,,
PC & Cable
(2) Turn on the PC & EDID Download Jig. And Execute the
S/W : EDID TESTER Ver.2.5
(3) Set up the S/W option
Repeat Number : 5
Device Address : A0
PageByte : 8
(4) Power on the Set
4-4. Sequence of Adjustment
DDC data of Analog-RGB
(1) Init the data
(2) Load the EDID data.(Open File).
(3) Set the S/W as below.
Copyright©2008 LG Electronics. Inc. All right reserved.
Only for training and service purposes
LGE Internal Use Only
ADJUSTMENT INSTRUCTIONS
TV set
or
Main B/D
(Fig. 1) Connection Diagram of DDC Download
Open File
Open File
[Analog – RGB :
PP78D_RGB.ANA ]
[Digital – HDMI :
PP78D_HDMI.DVI ]