Checking order
1, 2. Check IR cable condition between IR & Main board.
3. Check the st-by 3.3V on the terminal 6.
4. When checking the Pre-Amp when the power is in ON condition, it is normal when the
Analog Tester needle moves slowly, and defective when it does not move at all.
Standard Repair Process Detail Technical Manual
Remote controller operation checking method
D. Function error_ No response in remote controller,
key error
<ALL MODELS>
A27
Established
date
Revised
date
Error
symptom
Content
LCD TV
A27
1
2
P2401, P2402
1
EYEQ_SCL
2
EYEQ_SDA
3
GND
4
KEY1
5
KEY2
6
St 3.3V
7
GND
8
LED_B
9
IR
10
GND
11
Normal 3.3V
12
LED_R
13
GND
14
Soft Touch_SCL
15
Soft Touch_SDA
3
4
2011. 2 .07
Copyright © 2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
LGE Internal Use Only
Содержание 32LV355T