Direct LED W/B adjust target value (Only LGD direct LED, LM3100/LM3400 series)
Cool
Medium
Warm
x
y
x
y
x
y
Target
(Direct LED)
271
276
287
296
315
332
◈
Summary about W/B information
Model Information
W/B Information
Model
Maker
Type
Cool
(C50)
Medium
(0)
Warm
(W50)
W/B table for
LGD edge LED
47LS4100-CA
LGD
Edge LED
13000K
9300K
6500K
O
42LS4100-CA
LGD
Edge LED
13000K
9300K
6500K
O
32LS3500-CA
LGD
Edge LED
13000K
9300K
6500K
O
42CS460-CB
LGD
EEFL
11000K
9300K
6500K
X
32CS460-CB
LGD
EEFL
11000K
9300K
6500K
X
42LM3400-CC
LGD
Direct LED
13000K
9300K
6500K
X
42LM3100-CC
LGD
Direct LED
13000K
9300K
6500K
X
32LM3100-CC
LGD
Direct LED
13000K
9300K
6500K
X
55LM4600-CC
LGD
Edge LED
13000K
9300K
6500K
O
47LM4600-CC
LGD
Edge LED
13000K
9300K
6500K
O
※
Connecting picture of the measuring instrument (On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to auto controller or push Adjustment R/C P-ONLY
à
Enter the mode of White-Balance, the pattern will come out.
Auto-control interface and directions
1. Adjust in the place where the influx of light like floodlight around is blocked. (Illumination is less than 10ux).
2. Adhere closely the Color Analyzer ( CA210 ) to the module less than 10cm distance, keep it with the surface of
the Module and Color Analyzer
’
s Prove vertically.(80~100°).
3. Aging time
-. After aging start, keep the power on (no suspension of power supply) and heat-run over 5 minutes.
-. Using
‘
no signal
’
or
‘
POWER ONLY
’
or the others, check the back light on.