- 14 -
LGE Internal Use Only
Copyright ©
LG Electronics. Inc. All rights reserved.
Only for training and service purposes
5.1.6. Reference
(White Balance Adj. coordinate and color
temperature)
▪ Luminance: 204 Gray, 80IRE
▪ Normal line
model: (normal line)LN5xxx, LA6xxx, LA7xxx, LA8xxx
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
269
273
285
293
313
329
1
0-2
281
290
297
310
322
342
2
3-5
280
288
296
308
321
340
3
6-9
279
287
295
307
320
339
4
10-19
277
284
293
304
318
336
5
20-35
275
280
291
300
316
332
6
36-49
273
277
289
297
314
329
7
50-79
271
275
287
295
312
327
8
80-119
270
274
286
294
311
326
9
Over 120
269
273
285
293
310
325
▪ Aging chamber line
(Aging chamber) Model : LN5xxx, LA6xxx, LA7xxx, LA8xxx
▪ Standard color coordinate and temperature using
CA-210(CH-14) – by aging time
H/R Time(Min)
Cool
Medium
Warm
x
y
x
x
y
x
269
273
285
293
313
329
1
0-5
280
288
296
308
321
340
2
6-10
276
283
292
303
317
335
3
11-20
273
278
289
298
314
330
4
21-30
270
275
286
295
311
327
5
31-40
267
272
283
292
308
324
6
41-50
266
270
282
290
307
322
7
51-80
265
269
281
289
306
321
8
81-119
264
267
280
287
305
319
9
Over 120
263
266
279
286
304
318
5.2. Option selection per country
5.2.1. Overview
(1) Tool option selection is only done for models in Non-USA
North America due to rating
(2) Applied model: LA32B Chassis applied to CANADA and
MEXICO
5.2.2. Country Group selection
(1) Press ADJ key on the Adj. R/C, and then select Country
Group Menu
(2) Depending on destination, select US, then on the lower
Country option, select US, CA, MX.
Selection is done using +, - KEY
(3) Using DFT(Auto)
※
PC (for communication through RS-232C) -> UART Baud
rate : 115200 bps
Command : ah 00 00 DATA(Area Number(hexadecimal))
ITEM
DATA(Area Number)
AREA
AREA OPTION1
0
USA
1
CANADA
2
MEXICO
5.2.3. Tool Option inspection
▪ Press Adj. key on the Adj. R/C, then select Tool option
Model
Module
Tool
option1
Tool
option2
Tool
option3
Tool
option4
32LN5300-UB
LGD
545
41478
37004
12031
47LN5400-UA
LGD
1569
33286
37004
46847
55LN5400-UA
LGD(POLA)
2065
33286
37004
40703
50LN5400-UA
LGD
1825
33286
37004
48895
42LN5400-UA
LGD
1313
33286
37004
36607
42LN5300-UB
LGD
1313
41478
37004
03839
42LN5300-UB
AUO
9505
41478
37004
03839
42LN5300-UB
LGD(POLA)
1297
41478
37004
03839
39LN5300-UB
CMI(POLA)
5137
41478
37004
03839
39LN5300-UB
AUO(POLA)
9233
41478
37004
03839
32LN5300-UB CSOT(POLA)
4625
41478
37004
03839
32LN530B-UB
LGD
545
45574
37004
03839
32LN530B-UB
LGD(POLA)
545
45574
37004
03839
※
Tool option can be reconstructed by Software
5.3. Ship-out mode check (In-stop)
- After final inspection, press In-Stop key of the Adj. R/C and
check that the unit goes to Stand-by mode
Содержание 32LN5300
Страница 43: ......