Electrical Installation

Caution

Avoid all electrical hazards when installing, wiring,

operating and maintaining a panel.

Do not use panels of different electrical or

physical configurations in the same system.

Match the polarities of cables and terminals when

making the connections; failure to do so may

result in damage to the panel.

When reverse currents can exceed the value

marked on the name plate, a properly rated and

certified over-current device (fuse or circuit

breaker) must be connected in series with each

panel or string of panels.

The rating of the over-current device shall not

exceed the maximum series fuse rating marked

on the name plate.

The panel contains factory installed bypass

diodes located inside the junction box.

When installing the system, it is recommended to

install the lightning rod to protect the system.

The junction box should not be opened. Opening

the junction box may void the warranty.

Panels with a suspected electrical problem

should be returned to LG Electronics for

inspection and possible repair or replacement as

per the warranty conditions provided by LG

Electronics.

Electrical Connections

Modules may be connected in series and/or

parallel to achieve the desired electrical output as

long as certain requirements are met.

Please use only the same type of modules in a

combined source circuit.

Do not disconnect the module under load.

Shock hazard can occur near the solar modules

connection means.

Series Connection

The solar modules may be wired in series to

produce the desired voltage output.

The current of each module connected in series

should be same.

The maximum number of series connected

modules can be determined by basis on max.

system voltage, the 125% safety factor, and the

module Voc which can be checked in “Product

Specifications” in this document.

Do not exceed 80%

of maximum system voltage.

The maximum solar module configuration can be

found in “Product Specifications”.

              Series connection for more voltage

Parallel Connection

The solar modules may be combined in parallel

to produce the desired current output.

When modules are combined in parallel, the total

current is equal to the sum of currents from each

module.

The voltage of each module connected in parallel

should be same.

When connecting plural strings of modules in

parallel every series string or solar module must

be fused prior to combining with other strings.

By pass diodes are factory installed in the solar

modules.

Please refer to the applicable regional and local

codes for additional fusing requirements and

limitations on the maximum number of solar

modules in parallel.

Maximum series fuse rating is refer to “Product

specifications;page 8”.

A multiplying factor is required for increased

output of the PV modules. Under normal

conditions, a PV module is likely to experience

conditions that produce more current and/or

voltage than reported at standard test conditions.

Accordingly, the values of Isc and Voc marked on

this PV module should be multiplied by a factor of

125% when determining component voltage

ratings, conductor ampacities, fuse sizes, and

size of controls to the PV output.

Depending on national directives additional

safety factors might be applicable for overcurrent

protection.

             Parallel connection for more current

…………..

+

-

+

-

-

+

-

+

-

+

-

+

…………..

+

-

+

-

-

+

-

+

5

All manuals and user guides at all-guides.com

Содержание 315Q1K-A5

Страница 1: ...before operating your set and retain it for future reference www lg solar com Installation manual PV Solar MODULE P NO MFL69724902 Rev 00 N TYPE MODELS LGXXXQ1C K A5 All manuals and user guides at all guides com a l l g u i d e s c o m ...

Страница 2: ...ical Installation 6 5 Product Specifications 8 6 Disclaimer of Liability Disposal 10 7 Transporting and Storage 10 8 Appendix 11 Revisions Table Date Version Description of change Remark 2016 09 02 1 0 1st edition 2016 12 07 2 0 Add New Products Black Model 2 All manuals and user guides at all guides com ...

Страница 3: ...ould be more than 4 times the cable diameter at least Please use proper equipment connector wire and buttress for system configuration of the module It may result in damage or failure of the product Do not perform installation in rainy heavily windy or snowy days It may result in safety accident Do not make holes in the frame or glass of the module It may decrease the strength of the frame or brea...

Страница 4: ... time of installation Make sure flammable gases are not generated near the installation site Do not work alone Please work as part of a team of two or more people Wear a safety belt if working high above the ground Contact with electrically active parts of the panels such as terminals can result in burns sparks and lethal shock whether the panel is connected or disconnected Even partial shadowing ...

Страница 5: ...of each module connected in series should be same The maximum number of series connected modules can be determined by basis on max system voltage the 125 safety factor and the module Voc which can be checked in Product Specifications in this document Do not exceed 80 of maximum system voltage The maximum solar module configuration can be found in Product Specifications Series connection for more v...

Страница 6: ...r modules from LG meet the conditions of safety class Ⅱ The national directives must be respected Module frame Bolt Flat washer Star washer Cup washer Grounding wire Spring washer Nut Flat washer 6 Module Mounting The LG Electronics LGE Limited Warranty for solar modules is contingent upon modules being mounted in accordance with the requirements described in this section The solar modules are in ...

Страница 7: ...ts Mounting by using frame bolts holes Secure the solar module to the structure using the factory mounting holes Four M8 stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module The module may be fastened to a support using both the outer and inner bolt holes of the frame Each module should be securely fastened at a minimum 4 points on two opposit...

Страница 8: ...1700 1016 40 18 5 LG380Q1C A5 Yes 380 3 42 9 10 84 37 4 10 17 18 20 1000 MC4 05 8 1700 1016 40 18 5 LG385Q1C A5 Yes 385 3 42 9 10 85 37 7 10 22 18 20 1000 MC4 05 8 1700 1016 40 18 5 LG315Q1K A5 Yes 315 3 41 4 10 00 34 7 9 09 19 20 1000 MC4 05 8 1700 1016 40 18 5 LG320Q1K A5 Yes 320 3 41 6 10 06 34 9 9 18 19 20 1000 MC4 05 8 1700 1016 40 18 5 LG325Q1K A5 Yes 325 3 41 9 10 11 35 1 9 27 19 20 1000 MC...

Страница 9: ...Product Specifications Dimensions of Modules 9 60Cell Module Unit mm in All manuals and user guides at all guides com ...

Страница 10: ...eparately from the municipal waste stream 2 Old electrical products can contain hazardous substances so correct disposal of your old appliance will help prevent potential negative consequences for the environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources ...

Страница 11: ...e A B B A C C B A 4 point installation is allowed in the following cases 1 Slope roof If module is installed parallel to the rooftop d n i w s a h c u s d n a t s l a n o i t i d d a n a h t i w d e l l a t s n i f I f o o r t a l F 2 A 200mm 5 9 in B 400mm 15 7 in Front 6000Pa 125psf Rear 5400Pa 113psf m m 0 2 1 A 4 7 in 4point Front 1800Pa 37 5psf Rear 1800Pa 37 5psf C 120mm 4 7in Front 3200Pa 6...

Страница 12: ...gu Seoul 150 721 Korea Contact solarinfo lge com http www lg solar com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II BC IEC V1 EN 201609 All manuals and user guides at all guides com ...

Отзывы: