background image

11

PRODUCT SPECIFICATIONS 

N-TYPE

Rated electrical characteristic except power rating within -0/+3 percent are within 5 percent of measured.

Values at Standard

 

Test Condition(STC) : Irradiance 1000W/m

2

, Cell temp. 25

, 1.5AM

Electrical Properties

Mechanical Properties

Module 

Series

Model Name

Pmax

at STC

Power

Tolerance

Voc at 

STC

Isc at 

STC

Vmpp

at STC

Impp at 

STC

Max.

Series

Fuse

Rating

Max.

No. of

module

in series

Max.

System

Voltage

Connector Length Width Height Weight

W

%

V

A

V

A

A

V

mm

mm

mm

kg

LGXXXN1T-V5

LGXXXN2T-V5

LG310N1T-V5

LG410N2T-V5

310

0~3%

39.7

10.14

32.6

9.52

19

20

1000

MC4

MC4

1686

1016

40

17.1

LG315N1T-V5

315

0~3%

39.7

10.18

32.9

9.58

19

20

1000

MC4

1686

1016

40

17.1

LG320N1T-V5

320

0~3%

39.8

10.22

33.2

9.65

19

20

1000

MC4

1686

1016

40

17.1

LG325N1T-V5

325

0~3%

39.8

10.26

33.5

9.70

19

20

1000

MC4

1686

1016

40

17.1

LG330N1T-V5

330

0~3%

39.9

10.30

33.8

9.77

19

20

1000

MC4

1686

1016

40

17.1

LG335N1T-V5

335

0~3%

40.0

10.34

34.1

9.83

19

20

1000

MC4

1686

1016

40

17.1

LG340N1T-V5

340

0~3%

40.1

10.38

34.4

9.89

19

20

1000
1000
1000
1000

1000
1000

MC4

1686

1016

40

17.1

20

40

2024

1024

20.3

385

0~3%

49.4

10.10

40.3

9.56

16

LG415N2T-V5

MC4

20

40

2024

1024

20.3

390

0~3%

49.5

10.14

40.7

9.59

16

LG420N2T-V5

MC4

20

40

2024

1024

20.3

395

0~3%

49.6

10.18

41.1

9.62

16

LG425N2T-V5

MC4

20

40

2024

1024

20.3

400

0~3%

49.7

10.22

41.5

9.65

16

LG430N2T-V5

MC4

20

40

2024

1024

20.3

405

0~3%

49.8

10.26

41.9

9.68

16

1000

LG435N2T-V5

MC4

20

40

2024

1024

20.3

410

0~3%

49.9

10.30

42.3

9.71

16

Note) MC4 formal name : PV-KST4 / 6II-UR, PV-KBT4 / 6II-UR

Note) The Typical change in module efficiency at 200W/m   in relation to 1000W/m   is -2.5% (Min. -3.0%)  

should be selected according to the installation site conditions and local code.

“Max. No. of modules in series” is considering 125% of Voc. Actual number of connections

→ Plus (+) Connector : Male MC4 coupler (PV-KBT4/6II-UR)
→ Negative (-) Connector : Female MC4 coupler (PV-KST4/6II-UR)

Ø A

Ø A

◇ 

Female and male cable couplers

 

Male cable coupler 

※ 

See more information 

>>

http://www.multi-contact.com/

Female cable coupler 

2

2

Model 

Cable Cross Section 

Ø A (Cable outer diameter) 

Rated current 

MC4

4mm² 

5.5 ~ 9mm 

30A

12AWG 

Temperature Characteristics

NMOT

[   °C  ]

Pmax

[%/°C]

Voc

[%/°C]

Isc

[%/°C]

 42 ± 3

-0.36

-0.27

 0.03

NMOT (Nominal Module Operating Temperature) : Irradiance 800W/m  , 

ambient temperature 20℃, wind speed 1m/s

2

Electrical Properties(NMOT*)

Model

Model

310

LGXXXN1T-V5

Maximum Power (Pmax)

[W]

232

MPP Voltage (Vmpp)

[V]

30.6

MPP Current (Impp)

[A]

7.60

Open Circuit Voltage (Voc)

[V]

37.3

Short Circuit Current (Isc)

[A]

8.15

315

236

30.9

7.64

37.3

8.18

320

240

31.2

7.70

37.4

8.21

325

243

31.4

7.74

37.4

8.24

330

247

31.7

7.80

37.5

8.28

335

251

32.0

7.84

37.6

8.31

340

255

32.3

7.89

37.7

8.34

410

289

37.9

7.62

46.6

8.12

415

292

38.2

7.65

46.7

8.15

420

296

38.6

7.67

46.8

8.19

425

300

39.0

7.69

46.9

8.22

430

304

39.4

7.72

47.0

8.25

435

308

39.8

7.74

47.1

8.28

LGXXXN1T-V5

 42 ± 3

-0.36

-0.26

 0.03

LGXXXN2T-V5

LGXXXN2T-V5

Содержание 310N1T-V5

Страница 1: ...Please read this manual carefully before operating your set and retain it for future reference N TYPE MODELS LGXXXN1T V5 LGXXXN2T V5 www lg solar com Installation manual PV Solar MODULE MFL70700907 ...

Страница 2: ...onnection 07 General Wiring 07 Earth Grounding 07 MECHANICAL INSTALLATION 08 Module Mounting 08 Site Consideration 08 Mounting Methods 08 DISCLAIMER OF LIABILITY DISPOSAL 10 TRANSPORTING AND STORAGE 10 REVISIONS TABLE 10 PRODUCT SPECIFICATIONS 11 Electrical Mechanical Properties 11 Dimensions of Modules 12 Mechanical Installation methods Bolting Clamp Information Unloading Flow Guide 13 15 16 APPE...

Страница 3: ...ed modules must be treated with safety protection equipment Failure to comply may result in serious bodily injury or death No electrical parts like cables are located after installation between laminate and mounting structure Do Not reconnect or repair junction box cable It may occur spark or electric shock Do not bending junction box s cable While under stress it may occur module damage Cable ben...

Страница 4: ...the junction box of the module or pull the cable Do not remove the labels attached to the module Failure to comply may result in damage of the product If the installing modules on curved surface e g arch type as shown in the below picture do not forcefully modify the module in the installation when connecting it with the structure Only install the module in the place where the structure for the pa...

Страница 5: ...icro fiber cloth can be used for regular washing or It may result in a burn or injury Do not disassemble the solar module After installation or repair check that the solar module are operating properly In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module Do ...

Страница 6: ...lar modules electrical connections Modules may be connected in series and or parallel to achieve the desired electrical output as long as it sheet Please use only the same type of modules in a combined source circuit Do not disconnect the module under when it is operating Shock hazard may occur near the solar modules connection means When the module installing in series or in parallel e g using fo...

Страница 7: ...rks should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national state and local electrical codes and regulations and standards and location of grounding holes is provided in Product One M4 stainless steel bolt one nut one spring washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts wash...

Страница 8: ... B A x Y Excluded Operating Environments The solar modules from LG Electronics can not be This mounting method is by using frame bolt holes The mounting rails must run perpendicularly to the module long side operated in a location where they could come in direct contact with salt water or ammonia Shadow LGE solar module should be installed in a proper site that there is no shadowing affected by bu...

Страница 9: ...ch module should be securely fastened at a minimum 4 points on two opposite sides and location of mounting holes is provided in Product Tighten the bolt securely by using the combination Place the spring washer between the Flat washer and Nut Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules provided in Mechanic...

Страница 10: ...he environment and human health Your old appliance may contain reusable parts that could be used to repair other products and other valuable materials that can be recycled to conserve limited resources 3 You can take your appliance either to the shop where you purchased the product or contact your local government waste office for details of your nearest authorized WEEE collection point For the mo...

Страница 11: ... LG430N2T V5 MC4 20 40 2024 1024 20 3 405 0 3 49 8 10 26 41 9 9 68 16 1000 LG435N2T V5 MC4 20 40 2024 1024 20 3 410 0 3 49 9 10 30 42 3 9 71 16 Note MC4 formal name PV KST4 6II UR PV KBT4 6II UR Note The Typical change in module efficiency at 200W m in relation to 1000W m is 2 5 Min 3 0 should be selected according to the installation site conditions and local code Max No of modules in series is c...

Страница 12: ...12 Dimensions of Modules 60Cell Module 72Cell Module Unit mm in ...

Страница 13: ...0mm Front 2400Pa Rear 2400Pa Fig 5 Clamping Type Fig 6 Clamping Type A B B A C C B A A 200mm B 400mm Front 5400Pa Rear 4000Pa m m 0 2 1 A 4point Front 1800Pa Rear 1800Pa C 120mm Front 5400Pa Rear 1800Pa A 120mm m m 0 0 1 3 4 8 B 6point Front 5400Pa Rear 4000Pa Note All mechanical installation methods Fig 1 to Fig 6 in this appendix were not tested by VDE It is evaluated by LG internal test Mechani...

Страница 14: ...g 5 Clamping Type Fig 6 Clamping Type A B B A C C B A A 250mm B 400mm Front 5400Pa Rear 3000Pa m m 0 2 1 A 4point Front 1600Pa Rear 1600Pa C 120mm Front 3600Pa Rear 1600Pa A 120mm m m 0 0 1 12 0 1 B 6point Front 5400Pa Rear 3000Pa All mechanical installation methods Fig 1 to Fig 7 and bolting method in this appendix were not tested by VDE e t o N It is evaluated by LG internal test Mechanical Inst...

Страница 15: ...pring washer Nut Mounting Rail Four M8 5 16inch stainless steel bolts four nuts four spring washers and eight flat washers are recommended per solar module Bolting Method the modules Clamp system requirements Use corrosion resistant material clamps and hardware E G L y b y t i l i b i t a p m o c r o f t s e t o t s d e e n t i p m a l c l a i c e p s a e s u u o y f I The clamp should not be touc...

Страница 16: ... Block Standard Line Rope The position of rope have to be between block 1 and block 2 when you fasten a rope to pallet If you have not timber bar you can use a pallet which is longer than module size The crane hook have to be placed center of packaging For the balance of packaging the rope between the packaging and crane must be the same length Step 3 Loading unloading packaging A minimum of two o...

Страница 17: ...ea Contact solarinfo lge com http www lg solar com LG Electronics Deutschland GmbH Alfred Herrhausen Allee 3 5 65760 Eschborn Germany Contact service solar lge de LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws ...

Отзывы: