4. Total Assembly line process
4.1. Adjustment Preparation
· W/B Equipment condition
CA210
: CCFL/EEFL -> CH9, Test signal: Inner pattern(80IRE)
LED -> CH14, Test signal: Inner pattern(80IRE)
· Above 5 minutes H/run in the inner pattern. (“power on” key
of adjust remote control)
· Edge LED W/B Table is process of time (Only LGD Module)
CA210: CH14, Test signal : Inner pattern(80IRE)
* Connecting picture of the measuring instrument
(On Automatic control)
Inside PATTERN is used when W/B is controlled. Connect to
auto controller or push Adjustment R/C POWER ON ->
Enter the mode of White-Balance, the pattern will come out.
* Auto-control interface and directions
1) Adjust in the place where the influx of light like floodlight
around is blocked. (illumination is less than 10 lux).
2) Adhere closely the Color Analyzer (CA210) to the module
less than 10 cm distance, keep it with the surface of the
Module and Color Analyzer’s prove vertically.(80° ~ 100°).
3) Aging time
- After aging start, keep the power on (no suspension of
power supply) and heat-run over 5 minutes.
- Using ‘no signal’ or ‘full white pattern’ or the others,
check the back light on.
• Auto adjustment Map(RS-232C)
RS-232C COMMAND
[CMD
ID DATA]
Wb
00
00
White Balance Start
Wb
00
ff
White Balance End
** Caution **
Color Temperature : COOL, Medium, Warm.
One of R Gain/G Gain/ B Gain should be kept on 0xC0, and
adjust other two lower than C0.
(when R/G/B Gain are all C0, it is the FULL Dynamic Range
of Module)
* Manual W/B process using adjusts Remote control.
• After enter Service Mode by pushing “ADJ” key,
• Enter White Balance by pushing “
G
” key at “6. White
Balance”.
* After you finished all adjustments, Press “In-start” key and
compare Tool option and Area option value with its BOM, if
it is correctly same then unplug the AC cable. If it is not
same, then correct it same with BOM and unplug AC cable.
For correct it to the model’s module from factory Jig model.
* Push the “IN STOP” key after completing the function
inspection. And Mechanical Power Switch must be set “ON”.
4.2. DDC EDID Write (RGB 128Byte )
• Connect D-sub Signal Cable to D-sub Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
4.3. DDC EDID Write (HDMI 256Byte)
• Connect HDMI Signal Cable to HDMI Jack.
• Write EDID Data to EEPROM(24C02) by using DDC2B
protocol.
• Check whether written EDID data is correct or not.
* For Service main Assembly, EDID have to be downloaded to
Insert Process in advance.
- 11 -
LGE Internal Use Only
Copyright ©2011 LG Electronics. Inc. All rights reserved.
Only for training and service purposes
Cool
13,000
K
X=0.269(±0.002)
Y=0.273(±0.002)
<Test Signal>
Medium
9,300
K
X=0.285(±0.002)
Inner pattern
Y=0.293(±0.002)
(204 gray, 80 IRE)
Warm
6,500
K
X=0.313(±0.002)
Y=0.329(±0.002)
Full White Pattern
COLOR
ANALYZER
TYPE: CA-210
RS-232C Communication
CA-210
RS-232C COMMAND MIN
CENTER
MAX
[CMD ID DATA]
(DEFAULT)
Cool
Mid
Warm
Cool
Mid
Warm
R Gain
jg
Ja
jd
00
172
192
192
192
G Gain
jh
Jb
je
00
172
192
192
192
B Gain
ji
Jc
jf
00
192
192
172
192
R Cut
64
64
64
128
G Cut
64
64
64
128
B Cut
64
64
64
128
Aging Time
Cool
Medium
Warm
GP2R
(Min.)
X
Y
X
Y
X
Y
269
273
285
293
313
329
1
0-2
279
288
295
308
319
338
2
3-5
278
286
294
306
318
336
3
6-9
277
285
293
305
317
335
4
10-19
276
283
292
303
316
333
5
20-35
274
280
290
300
314
330
6
36-49
272
277
288
297
312
327
7
50-79
271
275
287
295
311
325
8
80-149
270
274
286
294
310
324
9
Over 150
269
273
285
293
309
323
EZ ADJUST
0. Tool Option1
1. Tool Option2
2. Tool Option3
3. Tool Option4
4. Country Group
5. ADC Calibration
6. White Balance
7. Test Pattern
8. EDID D/L
9. Sub B/C
10. V-Com
11. P-Gamma
White Balance
Color Temp.
R-Gain
G-Gain
B-Gain
R-Cut
G-Cut
B-Cut
Test-Pattern.
Reset
Cool
172
172
192
64
64
64
ON
To set