1, 2. Check IR cable condition between IR & Main board
3. Check the 3.4V_ST Voltage
Standard Repair Process Detail Technical Manual
①
②
< Sub Ass’y>
< Main Ass’y>
Error Symptom
D. Function Error, No Response in remote control, Key error
Established date
A16
Content
Remote control operation checking method
Revised date
P4101
1
+3.4V_ST
2
KEY1
3
KEY2
4
GND
5
LED_R
6
NC
7
GND
8
IR
③