25
EXTERNAL CONTROL DEVICE SETUP
ENG
ENGLISH
Command reference list
Communication parameters
y
y
Baud rate: 9600 bps (UART)
y
y
Data length: 8 bits
y
y
Parity : None
y
y
Stop bit: 1 bit
y
y
Communication code: ASCII code
y
y
Use a crossed (reverse) cable.
* Note : During USB operations such as DivX or EMF, all commands except Power(ka) and Key(mc) are not
executed and treated as NG.
(Depending on model)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
COMMAND1 COMMAND2
DATA
(Hexadeci-
mal)
01. Power
k
a
00 to 01
13. Treble
k
r
00 to 64
02. Aspect
Ratio
k
c
(
14. Bass
k
s
00 to 64
03. Screen
Mute
k
d
(
15. Balance
k
t
00 to 64
04. Volume
Mute
k
e
00 to 01
16. Colour
Temperature
x
u
00 to 64
05. Volume
Control
k
f
00 to 64
17. Energy
Saving
j
q
00 to 05
06. Contrast
k
g
00 to 64
18. Auto Con-
figuration
j
u
01
07. Brightness k
h
00 to 64
19. Tune Com-
mand
m
a
(
08. Colour
k
i
00 to 64
20. Programme
Add/Skip
m
b
00 to 01
09. Tint
k
j
00 to 64
21. Key
m
c
Key Code
10. Sharpness k
k
00 to 64
22. Control
Back Light
m
g
00 to 64
11. OSD Select k
l
00 to 01
23. Input select
(Main)
x
b
(
12. Remote
Control
Lock Mode
k
m
00 to 01
(Depending on model)
Содержание 22LJ620H
Страница 31: ......