– 29 –
ES-2010G / ES-2010GP
3
I
NSTALLING
THE
S
WITCH
This chapter describes how to install the switches.
S
ELECTING
A
S
ITE
◆
The site should:
■
be at the center of all the devices you want to link and near a power
outlet.
■
be able to maintain its temperature within 0 to 50 °C (32 to 122 °F)
and its humidity within 10% to 90%, non-condensing
■
provide adequate space (approximately two inches) on all sides for
proper air flow
■
be accessible for installing, cabling and maintaining the devices
■
allow the status LEDs to be clearly visible
◆
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference,
such as radios and transmitters.
◆
Make sure that the unit is connected to a separate grounded power
outlet that provides 100 to 240 VAC, 50 to 60 Hz, is within 2 m (6.6
feet) of each device and is powered from an independent circuit
breaker. As with any equipment, using a filter or surge suppressor is
recommended.
E
THERNET
C
ABLING
To ensure proper operation when installing the switch into a network, make
sure that the current cables are suitable for 10BASE-T, 100BASE-TX, or
1000BASE-T operation. Check the following criteria against the current
installation of your network:
◆
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair
(STP) cables with RJ-45 connectors; Category 3 or better for 10BASE-T,
Category 5 or better for 100BASE-TX, and Category 5, 5e, or 6 for
1000BASE-T.
◆
Protection from radio frequency interference emissions