Abnormal LOCKing
1. In case of the operation of LOCK is reversed :
1) Confirm the setting of LCM as “RelayOut#1”
2) Check the wire connection it is LOCK NC or NO.
-ex) Fail safe type should be set as LOCK NC.
3) Check the wire connection between XID-500 LOCK port with the electric LOCK
2. In case of unlocking, even though tagging RF-CARD :
1) Check the adjust setting of LCM.
2) Be sure the power coming form Adaptor or Power source
3. In case of the Deadbolt Lock (when door is closed, Deadbolt is not operated)
1) Confirm the setting of LCM
2) Check the position of the magnetic on the sensor
3) Check the door-icon of XID-500
4) Be sure the power coming form Adaptor or Power source
3. EM / Deadbolt / Strike
One-direction check-point