LEYBOLD SOGEVAC SV40 BI FC Скачать руководство пользователя страница 1

SOGEVAC

®

  

SV40-65 BI FC

Single-stage, oil-sealed rotary vane pump

Original Operating instructions 300452480_002_C1
and spare parts list

Part-Nr: 
960359V01
960361V01
960362V01
960363V01
960363V013001
960461V01ES
960462V01
960463V01
960465V013001
960465V013002
960466V01
and other variants

Содержание SOGEVAC SV40 BI FC

Страница 1: ...led rotary vane pump Original Operating instructions 300452480_002_C1 and spare parts list Part Nr 960359V01 960361V01 960362V01 960363V01 960363V013001 960461V01ES 960462V01 960463V01 960465V013001 9...

Страница 2: ...ring 12 3 Installation 13 3 1 Setting up 13 3 2 Electrical connections 14 3 3 Oil filling 16 3 4 Start up 16 4 Operation 16 4 1 Operation 16 4 2 Working in cycles in out 17 4 3 Switching off Shutdown...

Страница 3: ...irements and regula tions Address any further safety operation and or maintenance questions to our nearest office Failure to observe the following precautions could result in serious personal injury S...

Страница 4: ...ity and contact with fluids Avoid thermally stressing the lines by unfavourable laying Provide strain relief for the connecting lines so that the plugs and the line connectors are not subjected to exc...

Страница 5: ...ll work on a pump which is still warm from operation should be done only whilst wearing protective gloves Handle the pump only while vented and after having let it cool down Never remove the oil fill...

Страница 6: ...ansfer pushes the collected oil back into the vacuum generator the transfer is operated by a float valve to avoid atmospheric air coming from the oil casing to the inlet of the pump when no oil is pre...

Страница 7: ...nt in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This product has been tested to the requirements...

Страница 8: ...llast mbar 1 0 Water vapour tolerance with small gas ballast approx mbar 10 Water vapour tolerable load with small gas ballast approx kg h 1 0 41 Noise level Norme DIN 46 635 dB A 60 Motor power Rated...

Страница 9: ...gas ballast Courbes de d bit sans lest d air avec lest d air m 3 h 1 100 10 1 29 921 10 2 100 Torr 7 5 10 3 7 5 10 2 7 5 10 1 7 5 100 7 5 101 7 5 102 1Pa 10 2 mbar 1 Torr 1 33mbar D bit LA 50 60Hz 0...

Страница 10: ...MANN CA3GS Yes 2 Fuses 12 5 A 960362V01 SV40 BI FC Y1 25 KF 25 KF PFPE LVO 420 PTFE 9 Female RS485 HIRSCHMANN CA3GS Yes 2 Fuses 12 5 A 960363V01 SV40 BI FC Y1 25 KF 1 2 Barbed hose fitting LVO 200 Dyn...

Страница 11: ...5 971457CH Hirschmann Swiss plug 10 A 2 5 971457WW Hirschmann w o 2 5 EK6506966 Hirschmann IEC 309 16 A 5 EK6510715 Hirschmann C20 2 5 EK6520102 Hirschmann Cable shoes 5 mm 2 8 EK6510720 Hirschmann C1...

Страница 12: ...he lifting lugs which are provided on the pump to lift the pump with the specified lifting devices Make sure that these have been installed safety Use suitable lifting equip ment Make sure that all sa...

Страница 13: ...ary Additional warning note consider changes in ambient temperatures that might occur when air conditioning is turned down such as nights and week ends The pump must be kept clean no dust deposit Norm...

Страница 14: ...nection See Ordering information for the power supply interface type on the pump The power socket and cord are disconnection elements which must remain accessible to the users In de energized conditio...

Страница 15: ...NC pin 5 GND pin 6 NC pin 7 Data pin 8 NC pin 9 NC Sub D female for CONTROL P N 960363V013001 960463V01 960465V013001 960465V013002 960466V01 pin 1 NC pin 2 24V pin 3 NC pin 4 Low Speed pin 5 NC pin...

Страница 16: ...l unscrew the oil fill plug and fill in until the oil level reaches the MAX mark beside the oil sight glass 1 l oil is needed for the SV40 BI FC 2 l oil are needed for the SV65 BI FC 3 4 Start up Alwa...

Страница 17: ...sign of condensation of vapors in the pump is a rise of the oil level dur ing operation of the pump When vapors are pumped the pump must not be switched off immediately after completion of the process...

Страница 18: ...tarted by a manual action This applies equally to emergency cut off switches Close the gasballast 4 4 Conditions of use The Sogevac SV BI FC pumps are intended to be used on clean pro cesses at low in...

Страница 19: ...aintenance intervals Maintenance job Frequency Section Check the oil level Daily A Oil changes operation Annually B Longer with LVO700 Exhaust filter replacement Annually C Longer with LVO700 Gas ball...

Страница 20: ...ant environmental regu lations 5 4 Maintenance Work Checking the oil A Oil level The oil level shall be checked at least once a day and must be while the pump is in operation close to the MAX marks Sh...

Страница 21: ...rane the seat and the knob Reassemble in the reverse sequence E Anti suck back valve checking The anti suck back valve should be checked at the same time as the inlet flange sifter and if dirty be cle...

Страница 22: ...l lines Clean the oil casing Vacuum lines are dirty Clean vacuum lines Pump is too small Check the process date replace the pump if necessary Pumping speed is too low Precaution install a dust filter...

Страница 23: ...e of float valve is clogged Check the valve clean the nozzle 5 4 high oil mist at Oil level is too high Drain the excess oil 5 4 B exhaust Oil is turbid Condensation Degas the oil or change the oil an...

Страница 24: ...mbers in the spare parts list Consummables and main spare parts kits for Sogevac pumps are usual ly available on stock at Leybold s service centers The list of these parts is given hereafter and in th...

Страница 25: ...d Spare parts 42 1 2 3 4 5 6 7 8 9 9a 11a 11 12 11c 11d 13 14 15 16 17 18 21 20 22 23 4 24 25 5 26 27 26 28 43 29 31 32 33 34 35 40 40a 40b 41 A 10 38 11b 19 19a 19b 41a 30 44 38 37 36 39a 39 ECHELLE...

Страница 26: ...NGE 40KF EK971472860 Incl 4 20 21 22 24 1 EXHAUST VALVE 25 1 VALVE STOP 26 4 SCREW CHC M8 X 12 27 1 GASKET FKM 28 1 OIL SIGHT GLASS G3 4 29 1 PLUG M BARBED HOSE FITTING G1 1 4 M DN13 971444130 Incl 30...

Страница 27: ...27 300452480_002_C1 12 2017 Leybold E...

Страница 28: ...eVacuum Pumps Application Process B Condition of the equipment No1 Yes No Contamination No1 Yes 1 1 Has the equipment been used toxic 2 Drained Product service fluid corrosive 3 All openings sealed ai...

Страница 29: ...29 300452480_002_C1 12 2017 Leybold Notes...

Страница 30: ...ice zh leybold com Spain Leybold Hisp nica S A C Huelva 7 E 08940 Cornell de Llobregat Barcelona Sales T 34 93 666 43 11 F 34 93 666 43 70 sales ba leybold com Service T 34 93 666 46 11 F 34 93 685 43...

Отзывы: