DeviceNet™
ITR 200 D
Interface for IONIVAC
Interface Manual 17200138_002_C0
Part Numbers
230 253 230 257
Страница 1: ...DeviceNet ITR 200 D Interface for IONIVAC Interface Manual 17200138_002_C0 Part Numbers 230 253 230 257...
Страница 2: ...00 SD with DeviceNet interface 2 switching functions 230 253 DN 25 ISO KF 230 257 DN 40 CF R The catalog number No can be taken from the nameplate We reserve the right to make technical changes withou...
Страница 3: ...evice Supervisor Object States 15 2 3 4 S Device Supervisor Common Services 15 2 3 5 S Device Supervisor Object Specific Services 16 2 4 S Analog Sensor Object 17 2 4 1 Class Attributes 17 2 4 2 Insta...
Страница 4: ...35 USINT Unsigned short integer 8 bit Range 0 255 UDINT Unsigned double integer Range 0 4 294 967 296 FLOAT Floating point value Range according to IEEE 754 XXh Hexadecimal number Radix 16 XXd Decimal...
Страница 5: ...unction 1 Address switch 10 decimal 2 Address switch 1 decimal 3 DeviceNet connector 4 Data rate switch 5 Network status LED 6 Module status LED 7 Sensor cable connector Power analog I O RS232C I O an...
Страница 6: ...ion Function 9 Potentiometer for Setpoint A threshold adjustment 10 Potentiometer for Setpoint B threshold adjustment 11 Full Scale adjustment push button 1 5 Indicators and Switches Device state LED...
Страница 7: ...Filament status Emission Status LED off dark Both filaments OK on green One filament broken on green flashing Both filaments broken on red During device initialization the node address switches are r...
Страница 8: ...Contains the In stance number of the assembly used by this connection to send data 1 2 4 5 8 9 10 12 13 This vendor specific attribute facilitates the configuration of the data assembly sent by the I...
Страница 9: ...alue of this attribute increases by one 2 Get Max Instance UINT Maximum instance number of an object currently created in this class level of the device The largest instance number of a created object...
Страница 10: ...Access rule NV V Name DeviceNet data type Description of attribute 3 Get NV DeviceType SHORT STRING ASCII Text CG combination gauge 4 Get NV SEMI Standard Revision Level SHORT STRING Specifies the re...
Страница 11: ...Number of Manufacturer detail bytes Detail 0 ARRAY of Serial communication alarm 14 Get V Exception Detail Warning STRUCT of A structure of three structures containing a bit mapped repre sentation of...
Страница 12: ...s are determined by a logical OR of the related Exception Detail bits as indicated Bit Function 0 ALARM device common The alarm or warning is not specific to the device type or device type manufacture...
Страница 13: ...ion Detail 0 and Common Exception Detail 1 The specific exception associated with each of the bitmaps is given in the table below The SIZE for this revision is two 2 Bit Common Exception Detail 0 Comm...
Страница 14: ...Reading Invalid Device Exception Detail Warning 1 Pirani 0 0 0 0 0 Device Exception Detail Warning 2 Pirani 0 0 0 Electronics Warning 0 Device Exception Detail Warning 3 Hot cathode 0 0 0 Filament 2...
Страница 15: ...attribute 10h Set_Attributes_Single Modifies an attribute value 05h Reset Resets the device to the Self Testing state 06h Start Starts the device execution 07h Stop Moves the device to the Idle state...
Страница 16: ...ice to perform a set of diagnostic routines DS Object Service Parameter dictionary Parameter Form Description TestID USINT Type and possibly detail of diagnostic test to be performed TestID parameter...
Страница 17: ...Analog Sensor Instances 95 Get Active Instance Number UINT Identifies the object instance that is providing the Value which is copied into the Active Value for all input Assemblies and the Alarm Warni...
Страница 18: ...at transfer vacuum gauge pirani gauge part of the ITR 200 SD This instance is used to provide control and status information for the Pirani gauge part of the ITR 200 SD Attr ID Access rule NV V Name D...
Страница 19: ...ings 0 default Semantics section 95 Get V Sensor Alarm Struct of Byte Bit definitions of Sensor Alarms 0 default Semantics section 96 Get V Status Extension BYTE Bit mapped byte providing addi tional...
Страница 20: ...0 Zero 1 Full Scale 2 Hold Last Value 3 Use Safe Value For Safe State set to Use Safe Value this attribute holds the value to which the Value attribute will be set for object instance states other tha...
Страница 21: ...section 7 Get V Status BYTE Alarm and Warn ing State of this object instance Semantics section 10 Get NV Full Scale INT or specified by Data Type if supported The Value of Full Scale for the sensor Th...
Страница 22: ...Structure of Byte default 0 Semantics section 96 Get V Status Extension BYTE Bit mapped byte providing addi tional status bits Bit description 0 Reading Invalid 1 Overrange Exceeded 2 Underrange Exce...
Страница 23: ...is below 7 2 10 6 mbar 16 Bits are used as sensor faults Bits 8 16 are mapped to the Exception Detail Alarm 3 Bits 0 7 are mapped to the Exception Detail Alarm 2 Data Component Bit 7 Bit 6 Bit 5 Bit...
Страница 24: ...apped byte which indicates the Alarm and Warning Exception status of the object instance The following definition applies Bit Definition 0 High Alarm Exception 0 cleared 1 set 1 Low Alarm Exception 0...
Страница 25: ...specified attribute 10h Set_Attribute_Single Modifies an attribute value 2 4 4 Object Specific Services on Instance 1 Pirani Service Code Service Name Description of Service 4Ch Full Scale Adjust Per...
Страница 26: ...service Parameter Data type Semantics of Values Degas State BOOL 0 switches Degas OFF 1 switches Degas ON Degas is switched on only if the pressure is below 7 2 10 6 mbar 2 4 5 2 Set Emission State Se...
Страница 27: ...mitter will switch off the emission automatically in both modes 2 4 6 Behavior The following behavior with respect to Data Type applies The data type value will be set automatically based upon the fir...
Страница 28: ...the transmitter device Number Type Name 1 Input Pressure Value Active Instance 2 Input Exception Status and INT Pressure Value Active Instance 4 Input REAL Pressure Value Active Instance 5 Input Exce...
Страница 29: ...1 Input 0 INT Pressure Value low byte 1 2 Input 0 Exception Status Class 48 Instance 1 Attribute 12 1 INT Pressure Value low byte 2 Class 49 Active Value 4 Input 0 REAL Pressure Value low byte 1 2 Cla...
Страница 30: ...Ah SEEE EEEEb EMMM MMMMb MMMM MMMMb MMMM MMMMb S EEEE EEEEb MMM MMMM MMMM MMMM MMMM MMMMb 1 1 Sign Exponent Mantissa 1 S XYZd RSTUVd Sign 2 Exponent 127 Mantissa MMMMMMMMMMMMMMMMMMMMMMMb 2 23 NNNNNd d...
Страница 31: ...0 0 b 0 0 0 0 0 0 0 0 b 0 1000 0101b 100 1010 0000 0000 0000 0000b 1 0 1 1 Sign Exponent Mantissa 1 133 1 578125 1 2 133 127 1 578125 101 23 b 2 0000 0000 0000 0000 1010 100 4849664 8388608 d d Conve...
Страница 32: ...ection object attribute 9 which is allocated in the allocation choice byte This attribute defaults to 2500 2500 ms within explicit messaging connections and to zero within an I O con nection If the IN...
Страница 33: ...ocated but the EPR attri bute has not to be set to any value Read a Configured Assembly addresses as specified above Get single request ID Message body 414 00 0E 05 02 0E get produced connection path...
Страница 34: ...Start Up Procedure 34 17200138_002_C0 2016 10 Leybold Set single response ID Message body 413 80 C0 00 response on first fragment 413 80 C1 00 response on second fragment...
Страница 35: ...7200026_002 Leybold GmbH D 50968 K ln Deutschland 2 www leybold com Operating Manual Dual Filament Bayard Alpert Pirani Transmitter ITR 200 S ITR 200 SL ITR 200 SP ITR 200 SD 17200137_002 Leybold GmbH...
Страница 36: ...Notes 36 17200138_002_C0 2016 10 Leybold...
Страница 37: ...Declaration of Contamination 17200138_002_C0 2016 10 Leybold 37 Declaration of Contamination...
Страница 38: ...ada F 91940 Les Ulis cedex Sales and Service T 33 1 69 82 48 00 F 33 1 69 07 57 38 info ctb leybold com sales ctb leybold com Leybold France S A S Valence Factory 640 Rue A Berg s B P 107 F 26501 Bour...