Spa Specifications

  

 

ELECTRICAL AND PEDICURE SPA COMPONENT 
SPECIFICATIONS

 

 

All electrical connections MUST be made by a qualified, licensed electrician in accordance with Local & National 
Electrical and Building Codes. A 110V-50/60 Hz, 15 Amp, GFCI protected grounded circuit MUST be used to 
supply power to the Pedicure Spa. A dedicated circuit must be used with a GFCI. All wiring must conform to 
National & Local Electrical Codes

 

WARNING:

 

IT IS EXTREMELY IMPORTANT THAT THE FOOT SPA OPERATES WITH GFCI  PROTECTION

 

 

 

VERY IMPORTANT Both back of chair and seat are adjustable. When both are at maximum positions one must 
allow 18” (44cm) from back wall to foot spa. This minimum distance assures unobstructed recline. Failure to 
follow this required dimension might damage your spa components and plumbing connections, which will void 
your warranty. 

 

PEDICURE SPA SPECIFICATIONS: 

 

Construction: Marble composite, high gloss, acetone-proof gel coat. 

 

Two (2) electro-mechanical knobs control the drain and whirlpool. 

 

Electro-mechanically operated reclining, massaging, and sliding seat with hand held control. 

 

One (1) pipe-less whirlpool jet. (Pipe-free technology) 

 

Power drain or Gravity drain   

 

Extendable water spray positioned well above water line, air gap is accommodated with back-flow 
prevention required by plumbing code 

 

Depending on pedicure spa model, arms may swing open, swing up / down or slide forward / backward.

 

 

 

SPECIFICATIONS 

  

Spa Dimensions & Weights 
 
 
 
 
 
Adjustable Stool 

   L

 52”(132cm),   W=31”(79cm) w/ Tray 47" (120cm)  H=56”(142cm)  

  *Spa Fully Recline: 68” (172cm)  
   Empty Weight:             ~ 200 lbs.  
   Shipping Weight:         ~ 260 lbs.     
   Max. Handling Weight ~ 250lbs 
   Pedicure Stool: 12” – 13”.  Manicure Stool: 16.25” – 20”  

Spa Water Capacity 

 ~ 4.5 US Gallon 

Jet Motor 

   120 VAC. at 85W 60Hz  

Massage Motors,  
Seat Sliding & Reclining 

   24VDC, 2.5A x 5 

Discharge Pump 

 
   Motor – 120V at 85W 60 Hz    Maximum vertical lift: 3ft.   Flow rate 500 GPH @  floor level 

Power source 

   115 VAC, 60HZ,   Power needed per spa chair = 6 Amp  

Electrical Switches 

   One (1) electro-mechanical knob for the Whirlpool. Rated at 5A contact. 
   One (1) electro-mechanical knob for the Drain. Rated at 5A contact. 

Plug & Play Installation 

   Installation should be made with connection at the external interface parts.  
   Please consult with your local plumber. 

Safety 

 
   Versas® Pedicure Spa is UL listed. 
 

 
 

 

11 

Содержание VERSAS

Страница 1: ...sprint of this advertisement Lexor s footspa specification and prices may change without prior notice Pedicure Spas are intended for professional used only always follow your State Board s sanitation...

Страница 2: ...Recognition as published in the appropriate UL Directory As a supplementary means of identifying products that have been produced under UL s Component Recognition Program UL s Recognized Component Mar...

Страница 3: ...n Flow Pattern for Gravity Drain 8 Plumbing Flow Pattern for Power Drain under ground 9 Hot and Cold Water Supply Lines 10 SPA SPECIFICATION Electrical and Pedicure Spa Component Specifications 11 OPE...

Страница 4: ...THIS UNIT UNLESS THEY ARE CLOSELY SUPPERVISED AT ALL TIME LIRE LES INSTRUCTION DU FABRICANT AVANT DE METTRE EN MARCHE UTILISER SEULEMENT A L INTERIEUR COUPER LE COURANT AVANT DE PROCEDRE AU DEPANNAGE...

Страница 5: ...st Cushion 4 Massage Remote Control 5 Manicure Tray Optional 6 Tub Bowl 7 Footrest 8 Sani Drain System with Discharge On Off Knob 9 Hot Cold Water Mixer Valve 10 Dual Function Auto Fill Jet On Off Kno...

Страница 6: ...SPA to SPA RECOMMENDED CLEARANCE TOP CHAIR REVISION 1 FOLD AND UNFOLD BACK REST MASSAGE 1 To set backrest up Lift up the backrest until a Click is heard Make sure the lever is locked 2 before operati...

Страница 7: ...up Plug arm rest into seat frame until Click is heard Raise Tray to horizontal level and push in Step 2 Pull up this Lock Ring to remove Arm Rest Step 3 Lift Up this Latch to unlock the locking device...

Страница 8: ...mended since debris from broken rubber seal might clog water mixer Failure to do so may void your Warranty 3 Backflow preventer Due to differences in construction lay out of your Salon and City s plum...

Страница 9: ...__Installation POWER DRAIN Connect Drain System with Drain Pump Using schedule 40 PVC Power Drain Connect drain to meet local plumbing codes Flexible connection to the drain should be removable for ea...

Страница 10: ...lease follow below Determine if your spa chair is used for a new construction of a salon or a replacement spa chair 1 New construction Make sure to remove any and all debris and or dust from current h...

Страница 11: ...ctro mechanically operated reclining massaging and sliding seat with hand held control One 1 pipe less whirlpool jet Pipe free technology Power drain or Gravity drain Extendable water spray positioned...

Страница 12: ...level decreases simply add more water Whirlpool Starting Turn the Jet Knob located on the right side of the front panel to clockwise to turn on Turn counterclockwise to shut off Warning Do NOT turn O...

Страница 13: ...knob clockwise and release to turn off water The switch can be activated to turn on or turn off water any time during the Auto Fill cycle NOTE Activate this Auto Fill Jet Knob 1 When water is running...

Страница 14: ...RSION Turn Counterclockwise to remove Cap Cover Turn Clockwise to Close Cap Cover AUTOFILL SYSTEM USING PLASTIC LINER Option on QSpa Position the Trench Mark on impeller housing to 12 O clock Logo mus...

Страница 15: ...e Press again to turn off massage Auto and Manual mode will run for duration of 20min 2 Press any button Rolling Spot Kneading Tapping and Combine to enter Manual mode 3 Press Rolling Spot to stop rol...

Страница 16: ...shall be drained and all debris shall be removed from the spa basin 2 The spa basin must be cleaned with soap or detergent and water 3 The spa basin must be disinfected with an EPA registered disinfe...

Страница 17: ...ot require a technician onsite Phone support on Thanksgiving Christmas New Years Chinese New Year s and Independence Day are not available Shipping Damages Shipping damages must be claimed within 48 h...

Страница 18: ...INC 14800 GOLDENWEST ST WESTMINSTER CA 92683 USA CUSTOMER CARE TEL 1 800 559 3630 FAX 1 714 622 1740 www lexor com 2012 All Rights reserved Design and Specifications are subject to change without noti...

Отзывы: